Configuration
After the mechanical and electrical installation has been completed, use the following
to install MeterLink
configuration and verify meter performance.
4.1 

Set up the MeterLink

Procedure
1. Follow the instructions in the
2. Select File → Program Settings and customize the user-preferences (e.g. User name,
3. Connect to your meter. If your meter is not shown in the list, select Edit Meter
4.2 

Field Setup Wizard

Procedure
1. Use the Field Setup Wizard-Startup in MeterLink
2. Select Next to continue to General setup.
3. Use General setup to configure the meter's units system (U.S Customary or Metric
4. Select Next to continue to Frequency/Digital Outputs page.
5. Set the Frequency/Digital Outputs Sources for either a frequency output or a digital
6.
Installation manual
in order to establish connection with the meter to perform final
Meters Quick Start Manual
Company name, display units, Liquid Meter volume units and other interface
settings).
Directory and setup the connections properties.
that allow proper configuration for your meter (Temperature, Pressure, Meter
Corrections, Meter Outputs, Gas chromatograph setup, Continuous flow analysis
and View local display setup).
Selections on this page will affect other configuration selections.
units) volume units, flow rate time, low flow cutoff, contract hour, enable reverse
flow alarm, set meter time and notepad comments.
Note
The Meter's Units system configured on the General Page affect the units for the
optional Local Display items.
status.
a) Select the Source for each Frequency/Digital output and select the desired
drive Mode. The Mode options are Open Collector which requires an external
excitation voltage and pull-up resistor or TTL mode which outputs a 0-5 Vdc
signal.
b) Select Next to continue to Frequency Outputs page.
Note
Frequency outputs 1 and Digital outputs 1 are paired together. This then means that
the Digital outputs 1 will be set to report the status for the parameter for Frequency
outputs 1. Similarly, Frequency outputs 2 and Digital outputs 2 are paired together.
Additionally, each Frequency output has an A and B output phase.
MeterLink
Software for Gas and Liquid Ultrasonic
to setup software communications with the meter.
to select the check boxes
Configuration