The Rosemount Gas Ultrasonic Flow Meter design is available with an optional glass
endcap and a local display.
Figure 1-5: Transmitter electronics enclosure with local display and glass endcap
All Rosemount ultrasonic flow meter's U.L. safety listing is accomplished through the
combination of an explosion-proof transmitter electronics enclosure that houses the CPU
module, Power Supply board, I.S. Barrier board, Backplane board and optional LCD Display
board.
Note
The optional LCD Display requires firmware v1.04 or later and Uboot version, April 25,
2022.
The Base Electronics Enclosure that houses the Acquisition Module. Intrinsically safe
transducers and cable assemblies are designed for Class 1, Division 1, Groups C and D
areas without need of further protection when installed in accordance with the field wiring
diagram (refer to Rosemount drawing DMC-005324 in
1.6 

Meter specifications for 3411, 3412, and 3414

 WARNING
Contents may be under pressure.
When the meter is under pressure, DO NOT attempt to remove or adjust the transducer
holder.
Attempting to do so could release pressurized gases, resulting in serious injury or
equipment damage.
 WARNING
Contents may be hazardous.
The meter must be fully depressurized and drained before attempting to remove the T-200
transducer assembly. If gas or fluid begins to leak from the T-200 transducer stalk
assembly, stop immediately and reinstall T-200 stalk assembly.
Failure to comply could cause serious injury or equipment damage.