Operating instructions
Water Softening Unit SOFT-HT1B
63924
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information prior to initial operation.
Technical changes reserved!
Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further
developments.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

Advertisement

loading

Summary of Contents for NatureWater SOFT-HT1B

  • Page 1 Operating instructions Water Softening Unit SOFT-HT1B 63924 Illustration similar, may vary depending on model Read and follow the operating instructions and safety information prior to initial operation. Technical changes reserved! Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further developments.
  • Page 2 To allow for a trouble-free complaint or return, it is important to contact our customer service team before returning your goods. Retourenabteilung WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler – Germany E-mail: service@wiltec.info Tel: +49 2403 55592–0 Fax: +49 2403 55592–15 https://www.naturewater.eu Item 63924 Page 2 01 2024-1...
  • Page 3 3 m in length between the outlet of the softener and the inlet of the hot water boiler. If the 3-m connection line cannot be assured, it is recommended to install a non-return valve between the water softener and the hot water boiler. https://www.naturewater.eu Item 63924 Page 3...
  • Page 4 Flow rate ( ℓ ⁄ 1800 Tank volume (ℓ) Max. flow rate ( ℓ ⁄ 1500 Max. temperature (℃) Min. temperature (℃) ⌀ 18 Drain size (㎜) 26.16 (¾″) external thread Hose connection (㎜) https://www.naturewater.eu Item 63924 Page 4 01 2024-1...
  • Page 5 Brine tank and valve 3-way valve (2.5″) Casing Top cover Overflow fitting Drawer for salt addition 0615 FRP tank Control panel Stainless-steel tube Display 0914 FRP tank Display cover Central pipe Electrical control box https://www.naturewater.eu Item 63924 Page 5 01 2024-1...
  • Page 6 Functionality № Name Letter Name Intake Service Process Backwash Outlet softened water Brine and slow washing (down flow) Raw water Quick re-fill Tank 2 Re-fill Tank 1 Brine and slow washing (up flow) https://www.naturewater.eu Item 63924 Page 6 01 2024-1...
  • Page 7: Functions And Features

    When the user mustpped up the salt, he or she can press any button on the water supply station to stop the low salt alarm (after topping up salt, it takes about 6 hours to clear). https://www.naturewater.eu Item 63924...
  • Page 8 • As shown in the illustration below, the drain pipe and the overflow pipe must be secured with ring clamps to prevent leakage during water drainage. https://www.naturewater.eu Item 63924 Page 8 01 2024-1...
  • Page 9 The waste-water pipe (overflow pipe) must not be connected to the sewage system in a sealed manner, as otherwise the machine can no longer work normally or the waste water can no longer flow back to the machine due to the negative pressure. https://www.naturewater.eu Item 63924 Page 9...
  • Page 10 Make sure that the O-ring has been fitted. 3. Cut off one drain pipe and one overflow pipe as required and lay them accordingly (secure the hose with a clamp), arrange the drain and overflow pipes, and connect them to the drain. https://www.naturewater.eu Item 63924 Page 10...
  • Page 11 Then insert the large insert from the accessory kit into the slot of the bypass valve and the water pipe connection. Then connect the display connection cable of the control panel and cover the top cover assembly. https://www.naturewater.eu Item 63924 Page 11...
  • Page 12 Note! Please check whether the large insert on the bypass valve is inserted all the way to the bottom. Check that the sealing rings on the two bypass pipe connections are correctly installed. https://www.naturewater.eu Item 63924 Page 12 01 2024-1...
  • Page 13 Intake Note! Make sure that the large clip on the bypass valve is inserted all the way to the end. Ensure that the seals on the two bypass pipe connections are properly installed. https://www.naturewater.eu Item 63924 Page 13 01 2024-1...
  • Page 14 Once the fault or problem has been rectified, set the bypass valve to the operating position (push the pull rod to the position shown in Fig. 2) to restore the soft water supply. https://www.naturewater.eu Item 63924 Page 14...
  • Page 15 Water-mixing regulator Water-mixing plug Clockwise rotation 9. The general installation scheme is divided into two installation methods (as shown in the figures below). Fig. 4 Fig. 5 № Name № Name Transformer Clamp https://www.naturewater.eu Item 63924 Page 15 01 2024-1...
  • Page 16 After completing the above steps, switch on the system. Press to call up the brine and slow rinse option, then press once to call up the refill option. In the refill option, a certain amount https://www.naturewater.eu Item 63924 Page 16 01 2024-1...
  • Page 17 During this process, the water and elec- tricity must not be switched off and no buttons must be pressed. 6. First use After 5 min of drawing water from the tap, the softened water can be used normally. https://www.naturewater.eu Item 63924 Page 17 01 2024-1...
  • Page 18 The background mode is set by the manufacturer at the factory, e.g., backwash, brine and slow rinse, refill, quick rinse, wash time, etc. № Name № Name Menu/confirm Up button Manual/cancel Down button https://www.naturewater.eu Item 63924 Page 18 01 2024-1...
  • Page 19 In the parameter settings menu, press and hold or move up or down to change the individual parameter values. • Press the up and down arrow buttons simultaneously for 5 s to cancel the button lock. https://www.naturewater.eu Item 63924 Page 19 01 2024-1...
  • Page 20 Backwash time 0–99 Minutes Brine and slow rinse 0–99 Minutes time Brine refill time 0–99 Minutes Quick-rinse time 0–99 Minutes Resin volume 5–75 Litres Water hardness 50–800 Mg/ℓ https://www.naturewater.eu Item 63924 Page 20 01 2024-1...
  • Page 21 If a possible power failure lasts more than 3 days, the menu shown in Fig. K is displayed. It serves as a reminder to adjust the time. Operating procedure Operation → Backwash → Brine & low rinse → Refill brine → Quick rinse https://www.naturewater.eu Item 63924 Page 21 01 2024-1...
  • Page 22 “Raw water hardness setting” (to determine the raw water hard- ness, see the “Water hardness and testing” section). Once the water softener has been installed, the three parameters shown above must be set. https://www.naturewater.eu Item 63924 Page 22...
  • Page 23 The hardness expressed by the CaCO₃ content can be roughly divided into Degree of hardness Description 0–75 Very soft water 75–150 Soft water 150–300 Middle-hard water 300–450 Hard water 450–700 Very hard water 700–1000 Super-hard water > 1000 Extra-hard water https://www.naturewater.eu Item 63924 Page 23 01 2024-1...
  • Page 24 During normal use, the user does not need to carry out any further work on the softener, but simply needs to add a certain amount of salt to the brine tank at regular intervals. https://www.naturewater.eu Item 63924 Page 24...
  • Page 25: Troubleshooting Table

    2. Brine tank does not have 2. Ensure that brine tank is suffi- enough salt ciently filled with salt. 3. Obstruction of injector 3. Remove and clean injector. https://www.naturewater.eu Item 63924 Page 25 01 2024-1...
  • Page 26 2. Wiring of locating board with 2. Replace wiring. controller fails to work 3. Control board is faulty 3. Replace control board. E3 or E4 Flash Control board is faulty Replace control board. https://www.naturewater.eu Item 63924 Page 26 01 2024-1...
  • Page 27 WilTec Wildanger Technik GmbH Königsbenden 12 / 28 52249 Eschweiler Germany Important note: Reproduction and any commercial use (of parts) of this operating manual, requires a written permission of WilTec Wildanger Technik GmbH. https://www.naturewater.eu Item 63924 Page 27 01 2024-1...

This manual is also suitable for:

63924