Download Print this page

NatureWater 51865 User Manual

Automatic water softener

Advertisement

Quick Links

User's Manual
Automatic Water Softener
51865–51866, 52360–52364
Illustration similar, may vary depending on model
Read and follow the operating instructions and safety information before using for the first time.
Technical changes reserved!
Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further
developments.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

Advertisement

loading

Summary of Contents for NatureWater 51865

  • Page 1 User’s Manual Automatic Water Softener 51865–51866, 52360–52364 Illustration similar, may vary depending on model Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Illustrations, functional steps, and technical data may deviate insignificantly due to continuous further developments.
  • Page 2 To allow for a trouble-free complaint or return, it is important to contact our customer service team before returning your goods. Retourenabteilung WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler – Germany E-mail: service@wiltec.info Tel: +49 2403 55592–0 Fax: +49 2403 55592–15 https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 2 09 2022-1...
  • Page 3: Important Instructions

    • Washing: After softening, the resin bed needs to be washed. It needs to be washed until there are no more residues of the softening salt in the water flowing out. https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 3 09 2022-1...
  • Page 4 3 m not be able to be reached, a non-return valve should be installed inside the tube. • The pressure of the water entering must be comprised between 0.1 and 0.6 MPa. Do avoid a negative water pressure in any case. https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 4 09 2022-1...
  • Page 5 • Only fill in coarse softening salt. Pipes of the softening device № Name № Name Brine hose Water intake Water outlet Flow meter Overflow valve Sink https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 5 09 2022-1...
  • Page 6 The end of the BLFC key holder presenting the small cross-piece should be inserted into the brine connection first. № Name № Name Quick coupling Knob holder of flow meter Push-button of brine-line flow meter Brine connection Knob 4 of brine-line flow meter https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 6 09 2022-1...
  • Page 7 “10:30:00” is the current time; Backwashing “2Min” is the average length of the mode, counted down “30Min” is the average length of Brine and slow washing the mode, counted down, re-fill via “Down flow” https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 7 09 2022-1...
  • Page 8 • When adjusting a numeric value of a parameter, the values selectable can be shown one by one by pressing once the arrow-up or arrow-down key. The values selectable can also be https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 8 09 2022-1...
  • Page 9 After starting the device and during display of the valve mode, press the “ESC” and arrow-down key at the same time to access the system menu. Caution: These parameters have been adjusted in the factory. Do not modify; other- wise, unknown errors might occur. https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 9 09 2022-1...
  • Page 10 “08 L” is but an ex- ample. Do not modify this value; otherwise, the water cannot be treated optimally any longer. Adjust regeneration cycle. Adjust backwash. Adjust brine mixture. Adjust re-fill. Adjust quick washing. https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 10 09 2022-1...
  • Page 11 5. Then remove the injector filter and its O-ring with a screw driver. 6. Rinse and thoroughly clean all parts under clean, warm water. 7. Blow away the water remaining and re-install the parts in reversed order. Exploded view and parts list https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 11 09 2022-1...
  • Page 12: Troubleshooting

    Do a backwash of the device. Milky water Air in system Open drain valve to release air. Insufficient water softening Raw water of very poor quality Contact water supplier. Too long a regeneration time Re-initialise regeneration time. https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 12 09 2022-1...
  • Page 13 Re-do regeneration and make vice mode sure to choose the correct salt concentration. By-pass valve leak Replace gasket. Wastewater hose gasket defec- Replace gasket. tive Wrong water hardness adjusted Adjust correct water hardness. https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 13 09 2022-1...
  • Page 14 WilTec Wildanger Technik GmbH Königsbenden 12 / 28 52249 Eschweiler Germany Important Note: Reproduction and any commercial use (of parts) of this operating manual, requires a written permission of WilTec Wildanger Technik GmbH. https://www.naturewater.eu Item 51865–51865, 52360–52364 Page 14 09 2022-1...

This manual is also suitable for:

518665236052364