Thread a 30-amp, 240-volt, 4-wire, UL-listed
power cord with #10 AWG-minimum copper
conductor through the strain relief.
a
Terminal Block
UL-Listed Strain Relief
b
UL-Listed 4-Wire Power Cord
c
4
Transfer the appliance's ground wire from
behind the green ground screw to the center
screw of the terminal block.
5
Attach the two hot leads (black and red) of the
power cord to the outer terminal block screws.
6
Attach the neutral (white) wire to the center
screw of the terminal block
7
Attach the power cord ground wire to the
green ground screw.
8
Tighten all screws securely.
9
Reinstall the terminal block access cover.
b
e
d
White Wire moved from Ground Screw
a
Hot Leads of Power Cord (Black and Red)
b
c
Neutral Wire (White)
d
Power Cord Ground Wire
e
Ground Screw (green)
Four-Wire Direct Wire
• A UL-listed strain relief is
required.
• Use UL-listed 4-wire #10 AWG minimum
copper conductor cable. Allow at least 1.5 m
of wire to allow for removal and reinstallation
of the dryer.
1
Remove 12.7 cm of the outer covering from the
wire and remove 12.7 cm of insulation from the
ground wire. Cut off approximately 3.8 cm
from the other three wires and strip 2.5 cm
insulation from each wire. Bend the ends of the
three shorter wires into a hook shape.
INSTALLATION
c
b
a
1'' (2.5 cm)
a
5'' (12.7 cm)