Troubleshooting - Dimplex MFP 051E Installation And Operating Instructions Manual

Wall convector
Table of Contents

Advertisement

Available languages

Available languages

English
6.11.3. Assigning programs
Press the
ously for 3 s to open the programming
menu.
Using the + and – keys, select ON and
confirm with the
OFF ends the menu.
Pr is displayed. Press the
Use the + and – keys to assign each
weekday a program (P1 to P6), and in
each case confirm with the
See above for display of weekdays.
Use the + or – keys to select EXIT and confirm with the
key to end programming mode.
6.11.4.Preconfigured programs
Program
Settings
P1
Comfort temperature from 5 am to 9 am and
from 5 pm to 11 pm Monday to Friday.
P2
Comfort temperature from 5 am to 9 am,
from 12 pm to 2 pm and from 5 pm to 11 pm
Monday to Friday.
P3
Comfort temperature from 5 am to 11 pm at
the weekend.
6.11.5. User-defined programs
Press the
ously for 3 s to open the programming
menu.
Using the + and – keys, select ON and
confirm with the
OFF ends the menu.
Pr is displayed.
Use the + or – keys to select P4, P5 or P6 and con-
firm with the
key.
(Start time) for slot 1 is displayed. Confirm with
the
key.
Use the + or – keys to select the start time for slot
1 and confirm with the
(End time) for slot 1 is displayed.
Press the
key.
EN-8
and
keys simultane-
key.
key.
key.
and
keys simultane-
key.
key.
2302/A
MFP 051E, MFP 101E, MFP 151E, MFP 201E
Use the + or – keys to select the end time for slot 1
and confirm with the
Repeat these steps for slots 2 and 3.
Use the + or – keys to select EXIT and confirm with
the
key to end programming mode.
6.12. Resetting to factory settings
Press the
key for 10 s to reset the device to the
factory settings.
Comfort set temperature
ECO set temperature
Window monitoring
Key lock (simple or with code)
Display illumination
Entry tone
Temperature display
Temperature limit
Programming
7.

Troubleshooting

7.1. Calibration of displays
It is normal for there to be discrepancy between the
display on the device and on the thermometer. It is
possible to calibrate the two displays.
This setting can only be configured if your device is
set to between 17 and 23 °C. All doors and windows
must be closed.
Wait for the temperature in the room to stabilise (at
least 6 h) and try to avoid a situation where people
keep entering or leaving the room.
To calibrate the displays, the thermometer must be
positioned in the middle of the room at a height of
1.20 m from the floor. Do not place on a piece of fur-
niture.
In Comfort mode, press the
two potential outcomes:
The set temperature will flash: synchronisation is
possible.
Use the + and – keys to change the set tempera-
ture and confirm with the
is displayed: synchronisation is not possible.
You must wait until the temperature has stabi-
lised.
After 15 seconds of inactivity, the display will return to
its initial position.
key.
19 °C
15.5 °C
Activated
None
10 s
Activated
°C
Disabled
None
key for 3 s. There are
key.
www.dimplex.eu

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfp 101eMfp 151eMfp 201e

Table of Contents