2.2

What is an Interface Node IFN AI?

Definition
The interface node IFN AI allows the data sampling of six analog signals.
The maximum sampling frequency is 192 kHz per channel. The nodes are connected via
bus system (IEEE1394) with 400 Mbps with an industrial PC.
Application Area
 The IFN AI is suited for the application in the industrial environment, because of the
robust construction and the degree of protection IP67.
 The compact design of the IFN AI enables the application in space-saving ranges.
 Easy handling of IFN AI provides a fast commissioning and maintenance
 The product is designed for the application on a DIN Rail or for mounting angles.
Display
The IFN AI has one display (LED), analog input connectors, IEEE1394 connections and
one connection for Power Supply.
Status Display:
 PWR (green LED)
 LNK (yellow LED)
 ERR (red LED)
Input Sensor
conections and
LEDs
(Channel 1,3,5)
Power Supply
(PWR)
IEEE1394 Connection
(LNK0)
Name Plate
(Bottom side)
Picture 2 Front view IFN AI
SIPLUS CMS4000 IFN AI
Operating Instructions, 07/2021, A5E02297872A-AA
Input Sensor-
connections and
LEDs
(Channel 2,4,6)
IEEE1394 Connection (LNK1)
IEEE1394 Connection (LNK2)
Label Plate
UIK - Address
8