REV switch
Used to reverse the repeater shift (4600 kHz) to monitor a signal coming to a
REV
repeater. Setting this switch to ON in simplex operation locks the displayed fre-
@)
quency regardless of VFO, keyboard, and COM*.CH
operations. (* European
and British versions excluded.}
@
TX OFFSET switch
Used to set transmit frequency (+600 kHz) shifted from the displayed receive
frequency when transmitting.
AE:
For operation other than that of a repeater, place this switch to the ''S'' posi-
tion. This equalizes the transmit frequency with the receive frequency.
"+4'"
setting
shifts
+600 kHz;
''—"'
setting
shifts
—600 kHz
from
the
receive frequency when transmitting.
This operation is only effective in VFO and MR (M1~M3)
operations.
lf a shift frequency goes beyond the operating frequency range when depress-
ing the PTT switch to transmit, a beep will sound three times to indicate the
misoperation.
However, transmit frequency is emitted in simplex mode.
*With the optional TU-3 tone unit installed, either ''+'' or ''—'' setting of the
TX
OFFSET
switch
interconnects
the TU-3
2nd
tone
frequency
setting.
(* European and British versions excluded.)
@ REAR PANEL
©
@
ANT connector lead
Connect a 50-ohm antenna to this terminal.
@
DC Power Terminal
DC power input terminal. Connect the supplied power cord with plug. Input
voltage is 13.8 V DC.
Observe plus (+) and minus (—) polarity!
@® SP Terminal
Connect the supplied 8 ohm speaker to this jack.
# RIGHT SIDE PANEL
*
© ©
© ©
@
Remote jack
Used to connect the optional FC-10 unit, controlling the operation frequency.
7