ERLA11~16D + EBSH/X(B)11+16P30+50D
Daikin Altherma 3 R ECH₂O
4P663482-1C – 2023.05
#
Code
[9.8.5]
N/A
[9.8.6]
N/A
[9.8.7]
N/A
Description
Restriction: Only applicable if [9.8.4]=Smart
Grid.
Shows the Smart Grid operation mode sent by
the 2 incoming Smart Grid contacts.
Smart Grid operation mode:
Free running
Forced off
Recommended on
Forced on
See also below table (Smart Grid operation
modes).
Restriction: Only applicable if [9.8.4]=Smart
Grid.
To set if electrical heaters are allowed.
Allow electrical heaters:
No
Yes
Restriction: Only applicable in case of room
thermostat control, and if [9.8.4]=Smart Grid.
To set if room buffering will be enabled.
Enable room buffering:
No: The extra energy from the photovoltaic
panels is only buffered in the storage tank (i.e.
heat up the storage tank).
Yes: The extra energy from the photovoltaic
panels is buffered in the storage tank, and in
the space heating/cooling circuit (i.e. heat up
or cool down the room).
11
Configuration
|
Installer reference guide
229