7 MENU
SET-UP
MENU A SETTING
Menu A contains those items listed in the table below.
3
These are the more frequently changed functions.
Follow this procedure to change the settings:
1
Press the F.LOCK button for more than two
4
seconds to enter the Menu Set-up mode.
Pa
A
rey
aa
tua
2
If the B indicator appears, press the A/B button to
display the A indicator.
The menu number appears at the left of the
display and the current setting appears at the
center.
Select the menu number using the tuning control.
Select the setting using the UP or DOWN button.
After you have changed a setting, press the CLR
or F.LOCK button to exit the Menu Set-up mode.
| pie !
Description
Selections
'Default
Heterence,
1
No,
|
page
RF output power switches through three levels (100,
a
(ele)
50, and 10 W).
as
100/50/10
100
20
as
oO
Display brightness switches through five levels. _
i
OFF/d4/d3/d2/d1 |
d2
\
-
d
| gg | AGC mode switches between slow(S) or fast(F).
S/F
s
i
or
i
(SSB, CW and AM only. No selection in FM.)
(CWA)
|
|
IF filter select. (SSB, CW, and AM only. No selection
2.4kHz
!
03
in FM)
as
eek
cae
0.5/2.4/6.0kKHz
(AM:6.0kH2) | 20, 22,43
SSB/CW mode switches between two-steps (SSB)
a
and three-steps (ULC).
|
mee /OEG
we
oe
Tf
0S
CW keying delay switches between FULL (full break-
= FULL/100/200/300/
600
24
in}, or a value in milliseconds.
400/600/800/1000/
daa
|
1400/1800 ms
ee
CW offset switches through the range of 400 to 1000
=
| °% tz in 50 Hz steps. Sidetone is fixed at 800 Hz.
ES
ee eee
EN, Seep
07
| CWreverse function.
ON/OFF
OFF
23
08
Tuning control disable.
ON/OFF
OFF —
ante
09
Busy-Frequency Stop for program scan.
ON/OFF
ON
40
to
| Busy-Frequency Stop for program scan switches
o/t
0
:
40
| between Time Operated (0) and Carrier Operated (1).
'
i
Tt
Busy-Frequency Stop for memory scan.
ON/OFF
ON
:
40
12
Busy-Frequency Stop for memory scan switches
o/t
0
40
between Time Operated(Q) and Carrier Operated(|).
Memory channel scan switches between all memory
7
7
channels(ON)or only the desired channel group(OFF).
ON/OFF
ORE
3
|
RF meter sensitivity switches between X4 scale (ON)
FE
pale
or normal{OFF). Only available with 10 W selected.
ON/OFF
OF
ee
|
15
Subaudible tone frequency. OFF may not allow
ON/OFF
ON
20, 29
repeater access,
16
Frequency step size from microphone (SSB and CW
10/100/1k/5k/10kHz
40kHz
49
i,
modes only) switches through five step sizes.
ne
eres
aM
17
Frequency step size from microphone (FM and AM
10/100/1k/Sk/10kHz|
10kHz
49
J modes only) switches through five step sizes.
i
46