4-4. Duty Cycle And Overheating

Overheating
Notes
60% Duty Cycle
6 Minutes Welding
0
Minutes
4 Minutes Resting
15
OR
Reduce Duty Cycle
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed and
cooling fan runs. Wait fifteen min-
utes for unit to cool. Reduce amper-
age or voltage, or duty cycle before
welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
A or V
Ref. 219 523-A