PRODUCT SPECIFICATIONS AND PARTS

MODEL NUMBER: AC4870
DIMENSIONS: 9.25 in. x 5.5 in. x 21.5 in.
WEIGHT: 8.82 lbs.
INPUT VOLTAGE: 120 V 60Hz 55W

PRODUCT PARTS

CONTROL PANEL

CONTROL PANEL

Digital Air Purifying System

Improve your indoor air quality with your new Germ Guardian® Air Purifying System. Multiple levels of cleaning include a combination HEPA filter that captures allergens, and Charcoal filter to remove odors. UV-C light technology enhances germ-killing.

Pre-Filter*
Captures initial dust and allergen particles.

Charcoal Filter* (aka Activated Carbon)
Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs and mold.

HEPA Filter
Captures 99.97% of dust and allergens.

UV-C Light
UV-C light technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
*Pre-Filter and Carbon Filter are combined into one layer that attaches to the Filter.

AIR CLEANING LAYERS

AIR CLEANING LAYERS

COMBINATION FILTER


*Filter must be removed from plastic bag before use.
NOTE: Pre/Charcoal Filter is affixed to HEPA Filter with velcro.
Filter Package includes:

Filter lasts approximately 6-8 months depending on use.
*Filter Replacement Indicator: The HEPA reset light on the control panel will illuminate indicating that it is time to replace your filter. Replace the filter according to directions then push and hold Timer Button for 5 seconds to reset filter change indicator.
Depending on usage, filter will last approximately 6 months.
See "Cleaning & Maintaining Filter" for proper care of filter.

REPLACEMENT PARTS

FILTER:
Filter
Model No. FLT4825
UV-C BULB (5W):
Model No. LB4000
REPLACEMENT CARBON FILTER 4-PACK:
Model No. FLT22CB4

Check out our AutoShip & Save

Filter Replacement Program ™
www.guardiantechnologies.com

To maintain the performance of the air cleaner, use Guardian Technologies GENUINE Replacement Parts only.
To Purchase Contact Customer Service

What is CADR?
CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particles from things like tobacco smoke and plant pollens from the room.

Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.

OPERATING INSTRUCTIONS

BEFORE OPERATING THE AIR PURIFIER:

  1. Carefully remove your air purifier and combination filter from box and bag.
  2. Select a firm, level and flat location for the air purifier.
    • For proper air flow, locate the unit at least 1 foot from any wall or furniture.
    • Make sure none of the grills are blocked.
  3. Plug the power cord into a 120V AC outlet.


When moving the air purifier, always lift unit by the carrying handle located on the back.

OPERATING THE AIR PURIFIER:

  1. Turn unit power ON.
  2. Select fan speed MODE 1 - 5
    (1 = lowest speed setting; 5 = highest speed setting)
  3. Select UV-C ON or OFF using UV-C Power Button.
  4. TIMER: If you prefer to run the purifier for a specific number of hours, you can select between 1 and 8 hours on the display.

INSTALLING/REMOVING COMBINATION FILTER

The HEPA reset light on the control panel will illuminate indicating that it is time to replace your filter..

  1. Turn off and unplug the unit.
  1. Press the Lock & Release Button and remove the Rear Cover from the unit.

  1. Remove the used Combination Filter and dispose of it in the garbage.

  1. Remove new filter from box and bag. Insert into the unit. Consult the arrow on the filter for correct installation direction.

  1. Reattach the Rear Cover of the unit and securely latch into place.
  2. Push and hold Timer Button for 5 seconds to reset filter change indicator.

INSTALLING & REMOVING UV-C BULB

The blue light on the front of air cleaner will begin to flash continuously when it is time to replace the UV-C bulb. Replace the bulb according to the directions then press the UV control button and hold for 5 seconds to restart the system. The light should remain a constant blue.

  1. Remove the Rear Cover of the unit by pushing Lock & Release Button.

  1. After removing the Rear Cover from the unit, remove the Combination Filter.

  1. After removing the Combination Filter, use a Philips head screwdriver to remove two (2) screws and detach the UV-C Metal Shield.
    INSTALLING & REMOVING UV-C BULB - Step 1
  1. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit.
    INSTALLING & REMOVING UV-C BULB - Step 2
  1. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.
  2. Push and hold UV Control Button for 5 seconds to reset UV Bulb Change Indicator.


The UV-C Bulb should be replaced every 10 - 12 months depending on use.

CLEANING & MAINTAINING THE COMBINATION FILTER

The air purifier should be cleaned at least once every month and the outer Pre-Charcoal Filter attached to the HEPA Filter should be cleaned every month.
More frequent cleaning may be required depending on environmental conditions.

PRE-/CHARCOAL FILTER
Remove the Pre-/Charcoal Filter from the velcro strips on the HEPA Filter.
Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt. After cleaning, reattach the Pre-/Charcoal Filter to the HEPA Filter.
PRE-/CHARCOAL FILTER

HEPA FILTER
Remove the Combination Filter from the back of unit.
Remove the Pre-/Charcoal Filter to expose the HEPA Filter.
When the HEPA Filter turns from white to grey or black it should be replaced with a new one. If the HEPA Filter is still white, it does NOT need to be replaced.

Do NOT try to wash and re-use the Combination Filter.
Please contact Customer Service at or visit us at www.guardiantechnologies.com to purchase a replacement filter.
Replacement Filter: FILTER B (FLT4825)
NOTE:
The Combination Filter is one filter. The multiple layers include: the Pre-/Charcoal Filter and the HEPA Filter.

AIR PURIFIER
Use a clean, dry, soft cloth to wipe the external surface of the unit.
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.

Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents.

TROUBLESHOOTING GUIDE

PROBLEM SOLUTION

Unit does not operate

Check that the unit is plugged in. Call Customer Service.

Unit shuts off unexpectedly

Check that the unit is plugged into a working electrical outlet.
Check that the HEPA Filter is firmly in place.
Check that the Rear Cover is latched firmly in place.
Call Customer Service.

No air circulating from unit

Make sure the filters are clean. Replace if necessary.

Control buttons 'beep' when pushed

To shut off the 'beeping' sound when buttons are pushed:
  1. Press and hold the fan speed button for 3 seconds.
  2. Select ON/OFF.
    "Beeping" will automatically be reset to ON when the unit is unplugged.

HEPA reset light on the control panel is illuminating

Time to change the filter. Refer to installation of filter section.

AIR PURIFYING SYSTEM REPLACEMENT PARTS


Replacement Filter: FILTER B
Model No. FLT4825


Replacement UV-C Bulb:
Model No. LB4000

SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Failure to comply with the warnings listed below may result in electric shock or serious injury.
warningThis product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

  • Read all instructions before using appliance.

  • This portable luminaire has a polarized plug (one blade is wider than the other) as a feature to reduce the risk of electric shock. This plug will fit into a polarized outlet only on way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact qualified electrician. Never use an extension cord unless the plug can be fully inserted. Do no alter the plug.
  • To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet
  • Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs near heat registers, radiator, stoves or heaters.
  • To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
  • Extreme caution is necessary when any appliance is used by or near children or people with disabilities and whenever the appliance is left operating unattended.
  • Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
  • NEVER drop or insert any object into any openings.
  • DO NOT run cord under carpeting.
  • DO NOT cover cord with throw rugs, runners, or similar coverings.
  • DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  • DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service for assistance.
  • Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
  • DO NOT use outdoors.
  • NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
  • DO NOT place anything on top of unit.

  • To reduce the risk of fire or electric shock, do not use this fan with any solidstate speed control device.

  • Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect power before replacing lamp or servicing.
    Replace Lamp With Lamp Model No. LB4000, Manufactured by Guardian Technologies.
  • Always unplug the unit before cleaning or servicing in any way.

  • Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.

The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m3 chamber. The product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on averaging time of 8 hours, is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m3.


Cancer or Reproductive Harm.
For more information go to www.P65Warnings.ca.gov.

LAMP CONTAINS MERCURY


Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010

This product earned the ENERGY STAR label by meeting strict energy efficiency guidelines set by the U.S. EPA. Room air cleaners have demonstrated the potential for improving air quality and providing health benefits. EPA does not endorse manufacturer claims regarding the degree to which a specific product will produce healthier indoor air. The energy efficiency of this ENERGY STAR certified model is measured based on a ratio between the model's CADR for Smoke and the electrical energy it consumes, or CADR/Watt.

Customer Service 1.866.603.5900
www.guardiantechnologies.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Guardian AC4870 - GermGuardian 22" Air purifier tower with HEPA filter & UV-C Manual

Advertisement

Need Assistance?

Do you have a question about the AC4870 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents