PRODUCT SPECIFICATIONS AND PARTS

MODEL NUMBER: AC4850PT
DIMENSIONS: 9.25in x 5.5in x 21.5in
WEIGHT: 8.82 lbs
INPUT VOLTAGE: 120 V 60Hz 55W
REPLACEMENT FILTER: FILTER BPET (FLT4850PT)
REPLACEMENT BULB: LB4000
BULB: 5W

PRODUCT PARTS

CONTROL PANEL

CONTROL PANEL OVERVIEW

Digital Air Cleaning System

Improve your indoor air quality with your new Germ Guardian® Air Cleaning System. Multiple levels of cleaning include a combination filter that captures allergens and mites, and Charcoal filter to remove odors. UV-C light technology enhances germ-killing.

Pre-filter*
Captures initial dust and allergen particles.

Charcoal filter* (aka Activated carbon)
Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs and mold.

Filter
Reduces allergens.

UV-C light
UV-C light technology works with Titanium Dioxide (TiO2) to enhance the elimination of airborne germs. TiO2 is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
*Pre-Filter and Charcoal Filter are combined into one layer that attaches to the Filter.

AIR CLEANING LAYERS

AIR CLEANING LAYERS

COMBINATION FILTER

COMBINATION FILTER
*Filter Replacement Indicator: The reset light on the control panel will illuminate indicating that it is time to replace your filter. Replace the filter according to directions then insert pen tip into Reset area on control panel to restart the system. Depending on usage, filter will last approximately 6 months. See "Cleaning & Maintaining Filter" for proper care of filter.

Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
This air cleaner is suggested for use in a single, closed room up to 155 square feet.
Higher CADR rates provide improved performance in all room sizes. Portable air cleaners will be much more effective in rooms when all the doors and windows are closed.

TOBACCO SMOKE: 100+
This value represents performance that can be expected within the first 72 hours of operation. Subsequent use may vary with use.
Tested per ANSI/AHAM AC-1 National Standard

What is CADR?
CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particules from things like tobacco smoke and plant pollens from the room.

INSTALLING & REMOVING COMBINATION FILTER

  1. Turn off and unplug the unit.
  1. Press the Lock & Release Button and remove the Rear Cover from the unit.

  1. Remove the used Combination Filter (Filter B) and dispose of it in the garbage.

  1. Remove new filter from box and bag. Insert into the unit. Consult the arrow on the filter for correct installation direction.

  1. Reattach the Rear Cover of the unit and securely latch into place.

OPERATING INSTRUCTIONS

BEFORE OPERATING THE AIR PURIFIER

  1. Carefully remove your air purifier and combination filter from box and bag.
  2. Select a firm, level and flat location for the air purifier.
    * For proper air flow, locate the unit at least 1 foot from any wall or furniture.
    * Make sure none of the grills are blocked.
  3. Plug the power cord into a 120V AC outlet.


When moving the air purifier, always lift unit by the carrying handle located on back.

OPERATING THE AIR PURIFIER

  1. Turn unit power ON.
  2. Select fan speed MODE 1 - 5
    (1 = lowest speed setting; 5 = highest speed setting)
  3. Select UV-C ON or OFF using UV-C Power Button.
  4. TIMER:
    If you prefer to run the purifier for a specific number of hours, you can select between 1 and 8 hours on the display.

INSTALLING & REMOVING UV-C BULB

  1. Remove the Rear Cover of the unit by pushing Lock & Release Button.

  1. After removing the Rear Cover from the unit, remove the Combination Filter.

  1. After removing the Combination Filter, use a Philips head screwdriver to remove two (2) screws and detach the UV-C Metal Shield.

  1. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit. (Fig. 4).
    INSTALLING & REMOVING UV-C BULB
    The UV-C Bulb should be replaced every 10 - 12 months depending on use. Please contact Customer Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement bulb. Replacement uv-c bulb: lb4000.
  2. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.

CLEANING & MAINTAINING THE COMBINATION FILTER

The air purifier should be cleaned at least once every month and the outer Pre-/ Charcoal Filter attached to the Filter should be cleaned every month. More frequent cleaning may be required depending on environmental conditions.

PRE-/CHARCOAL FILTER
Remove the Pre-/Charcoal Filter from the velcro strips on the Filter. (Fig. 6) Clean with the brush attachment of your vacuum cleaner. This will remove lint and dirt. After cleaning, reattach the Pre-/Charcoal to the Filter.
CLEANING & MAINTAINING THE COMBINATION FILTER
Remove the Combination Filter from the back of unit.
Remove the Pre-/Charcoal Filter to expose the Filter.
When the Filter turns from white to gray or black it should be replaced with a new one. If the Filter is still white, it does NOT need to be replaced.


Do NOT try to wash and re-use the Combination Filter. Please contact Customer Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement filter.
Replacement filter: FILTER B PET (FLT4850PT
Note
: The Combination Filter is one filter. The multiple layers include: the Pre-/Charcoal Filter and the Filter.

AIR PURIFIER
Use a clean, dry, soft cloth to wipe the external surface of the unit.
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.

Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.

TROUBLESHOOTING GUIDE

PROBLEM SOLUTION

Unit does not operate

Check that the unit is plugged in.
Call Customer Service 1.866.603.5900.

Unit shuts off unexpectedly

Check that the unit is plugged into a working electrical outlet.
Check that the Filter is firmly in place. Check that the Rear Cover is latched firmly in place. Call Customer Service 1.866.603.5900.

No air circulating from unit

Unplug unit. Check Pre-/Charcoal Filters. Clean Pre-/Charcoal Filter if necessary.
Replace Filter if necessary.

Increase in noise level

Make sure the filters are clean. Replace if necessary.

Safety instructions

READ AND SAVE THESE INSTRUCTIONS

warningThis product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.

THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USING.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

  • Read all instructions before using appliance.

  • This portable luminaire has a polarized plug (one blade is wider than the other) as a feature to reduce the risk of electric shock. This plug will fit into a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use an extension cord unless the plug can be fully inserted. Do not alter the plug.
  • To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
  • Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.
  • To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
  • Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the unit.
  • Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
  • NEVER drop or insert any object into any openings.
  • DO NOT run cord under carpeting.
  • DO NOT cover cord with throw rugs, runners, or similar coverings.
  • DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  • DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.
  • Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
  • DO NOT use outdoors.
  • NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
  • DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
  • DO NOT place anything on top of unit.

  • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

To Order Contact Customer Service
1.866.603.5900 or log on to www.guardiantechnologies.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Guardian AC4850PT - GermGuardian 3-in-1 Digital Air Cleaning System Manual

Advertisement

Need Assistance?

Do you have a question about the AC4850PT that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents