Panasonic NN-6207 Service Manual page 13

Hide thumbs Also See for NN-6207:
Table of Contents

Advertisement

T2=70 XK
Remember, the T1 time starts after the 50 second refreshing period.
The coefficient K is programmed into the microprocessor memory
and they are listed in the following tables along with the Pi and P2
powers. (See Fig. 14A and Fig. 14B)
A4:
T2=T1
XK
= 2 min. and 45 sec. X 2.5
= 160 sec. X 2.5
== 400 sec.
= 6 min. and 40 sec.
Example2: If the T1 time is measured to be,15 minutes and 30 seconds
after the 50 second period, and the Auto program selected is
FROZ-COOK A2:
T2=T7T1 XK
= 15 min. and 30 sec. X 0.5
= 980 sec. X 0.5
== 465 SEC. .
= 7 min. and 45 sec.
NN-6207, NN-6307, NN-6407
NN-6507, NN-6567, NN-6607, NN-6757
NN-6707, NN-6807
COOK, COOK-WARM
Pi
P2
K factor
Power
Power
Standard
Pa foe [Te
Ps [won [eft
ns [omen | omen | 132
approx. 1.6/2.4 approx. 1/1.6
pe oo [eso fo
Fig. 14A
B
wn
approx. 1.0
approx. 1.6
approx. 2.0
approx. 0.8/1.2
FROZ - COOK, FROZ-COOK-WARM
Power
Power
Standard
ie [J
Pa | [oe [oe few iac oe |
Pa | wow [0s forms ven ee |
Pe | we Poor [a feos |
Fae ae oe evar ces
Fa [wo [wor [0s fowmos feces |
e[wf—-fe[e [1
Pa [ wo [om [os oom ree
Pe [wo [ior [a6 feos feces |
Fig. 14B

Advertisement

Table of Contents
loading

Table of Contents