IV.
VALUE
CHECKING
* Coil block resistance
Coil block for alarm
:
1.8KQ ~ 2.4KQ
Coil block for chronograph
minute :
1.8KQ ~ 2.4KQ
Coil block for chronograph
second :
1.7KQ ~ 2.3KQ
Coil block
:
1.7KQ ~ 2.3KQ
* Upconverter coil resistance:
452 - 60Q
* Current consumption
Before
measuring
current consumption,
be sure to reset the circuit.
* Refer to "A necessary step after installing the battery".
For the whole of the movement
Time mode
:
less than 2.5uA
Stopwatch
mode
:
less than 10.0pA
For the circuit block alone
Time
mode
:
less than
1.81A
* Time accuracy
When
measuring the accuracy, make sure that the crown for alarm (at the 4 o'clock side) is at the first
or second click position.
V.
CHECKING OF THE FUNCTIONS
>, Button ®
Crown
/
*
g-reset adjustment
of the chronograph
hands
1)
Pull out the crown at the 3 o'clock side all the way to the second click.
2)
Keep buttons "A" and "B" pressed at the same time for more than 1 second.
3)
Press button "B" to reset the stopwatch second hand to "0".
4)
Press bution
"A" to reset the stopwatch minute hand to "0".
* With each press of buttons "B" and "A", the stopwatch second and minute hands move 0.2 seconds
and 0.5 minutes, respectively.
They move automatically while the buttons are kept pressed and
stop if they are released.