Error
type
Floor
Sensor
discon-
nected
Floor
Sensor
short-
circuited
Ther-
mostat
over-
heated
Unrecov-
erable
error
16
Nr.
Description
E1
Connection
to sensor is
lost
E2
Sensor
short-
circuited
E3
Thermostat
is over-
heated,
heating is
turned o
E4
Room
temperature
sensor value
too high or
too low
Danfoss ECtemp™ Smart
Solu-
Need restart
tion
Contact
The thermostat
service
requires a restart
to operate again.
Contact
The thermostat
service
requires a restart
to operate again.
Wait
The thermostat
until
requires no
ther-
restart, but will
mostat
start heat-
cools
ing when the
down
temperature is
lowered
Contact
The thermostat
service
requires a restart
to operate again.