Mounting On A Pedestal - Siemens SIMATIC NET SCALANCE M812 Operating Instructions Manual

Industrial remote communication
Hide thumbs Also See for SIMATIC NET SCALANCE M812:
Table of Contents

Advertisement

4.7

Mounting on a pedestal

Installation
1. Place the third housing guide of the device on the top edge of the pedestal
2. Press the device down against the pedestal until the spring catch locks in place
3. Connect the power supply, refer to the section "Power supply (Page 51)".
4. Fit the connectors for the digital input and digital output, refer to the section "Digital input/
output (Page 52)".
5. Connect the device to the DSL connection, refer to the section "DSL interface (Page 55)".
6. Connect the device to the local network, refer to the section "Ethernet port (Page 56)".
7. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-sectional
area ≥ 1.5 mm² to the functional ground of the system, see section "Grounding (Page 52)
" and section "Terminals (Page 26)".
Dismantling
1. Disconnect all connected cables.
2. Using a screwdriver, pull down the catch on the rear of the device.
3. Remove the device from the pedestal.
SCALANCE M812, M816
Operating Instructions, 11/2023, C79000-G8976-C343-09
Installation and removal
4.7 Mounting on a pedestal
.
.
45