Scanner And Cable Terminations; Scanner Pinout Connections - Honeywell Orbit 7120 User Manual

Presentation laser scanner
Hide thumbs Also See for Orbit 7120:
Table of Contents

Advertisement

S
CANNER AND

Scanner Pinout Connections

The 7120 scanner interfaces terminate to a 10-pin modular socket. The serial
number label indicates the interface enabled when the scanner is shipped from
the factory.
MS7120-47 Keyboard Wedge
and Stand-Alone Keyboard
Pin
Function
1
Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4
PC Data
5
PC Clock
6
KB Clock
7
PC +5V
8
KB Data
9
+5VDC
10
Shield Ground
MS7120-106
RS485 and Full Speed USB
Pin
Function
1
Ground
2
RS232 Transmit Output
3
RS232 Receive Input
4
IBM A+
5
IBM B-
6
USB D+
7
USB +V
8
USB D-
9
+5VDC
10
Shield Ground
27
C
T
ABLE
ERMINATIONS
Figure 19.
Pin
1
2
3
4
5
6
7
8
9
10
RS232 Full Speed USB
Pin
1
2
3
4
5
6
7
8
9
10
MS7120-41
RS232C
Function
Ground
RS232 Transmit Output
RS232 Receive Input
RTS Output
CTS Input
DTR Input/LTPN Source
Reserved
LTPN Data
+5VDC
Shield Ground
MS7120-38
Function
Ground
RS232 Transmit Output
RS232 Receive Input
RTS Output
CTS Input
D+
V USB
D-
+5VDC
Shield Ground

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ms7120

Table of Contents