The Smart Image status will also be stored after the monitor is resumed from AC on/off or
power switch on/off.
Linkage between SmartImage OSD and main OSD
A. Settings within main OSD have linkage with Smart Image OSD.
i. Brightness
ii. Contrast
iii. Color Temperature
B. Because each preset profiles will define default setting of these 3 parameters. Users
can understand what is the value of that in preset profile by open the main OSD.
C. When any SmartImage profile had been enabled. The parameters in main OSD are still
available for user to adjust. But these adjustments are temporary only. If users switch to
another profile and then go back. The setting in main OSD will show preset values of that
SmartImage profile enabled.
Profile Definitions (system integrators to input at design stages)
A. Office
i.
ii.
B. Photo
i. Purpose: Design for image viewing application, especially in slide show. The screen is
dominated by picture. Power point presentation could use this profile also.
ii. Enhancement Point:
2010/11/30
General Product Specification
Purpose: Design for general office application, like word processing, Spreadsheet
and email. The screen is dominated by text.
Enhancement point:
1. A little sharpness for increasing the details of e.g. an excel grid.
No other type of enhancement as it won't bring value.
2. Color temperature remains in 6500°K.
3. Brightness level should be 70%.
4. Smart Response set to "Off".
5. Smart Contrast set to "Off".
6. Gamma set to 2.2
1. Dynamic contrast enhancement by histogram analysis (DLC) should be off.