Navien NPE Installation & Operation Manual page 36

Condensing water heaters
Table of Contents

Advertisement

Ref
Description
F
Clearance to outside corner
G
Clearance to inside corner
Clearance to each side of center line extended above
H
meter/regulator assembly
I
Clearance to service regulator vent outlet
Clearance to nonmechanical air supply inlet to building
J
or the combustion air inlet to any other appliance
K
Clearance to a mechanical air supply inlet
Clearance above paved sidewalk or paved driveway
L
located on public property
M
Clearance under veranda, porch deck, or balcony
1 In accordance with the current CSA B149.1 Natural Gas and Propane Installation Code
2 In accordance with the current ANSI Z223.1 / NFPA 54 National Fuel Gas Code
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* Clearance in accordance with local installation codes and the requirements of the gas supplier.
36
Installing the Water Heater
Canadian Direct Vent Installations
*
*
3 ft (91 cm) within a height 15
ft above the meter/regulator
assembly
3 ft (91 cm)
36 in (91 cm)
6 ft (1.83 m)
7 ft (2.13 m) †
12 in (30 cm) ‡
1
US Direct Vent Installations
*
*
*
*
12 in (30 cm)
3 ft (91 cm) above if within 10
ft (3 m) horizontally
*
*
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents