4.2.12 PCBA-Embroidery module detection
See ESD-related note
Disassembly:
• Remove the covers (see 4.1)
• Picture 1 - Disconnect plug a.
• Picture 2 - Remove three screws c (T10 (3x8)
from base plate.
• Remove entire unit.
Assembly:
•
Picture 2 - Refit PCBA-Embroidery module
detection. Refit and retighten three screws c
T10.
•
Picture 1 - Lay PCBA-Embroidery module
detection unit wire in such way that it won't be
damaged when refitting the cover. Reconnect
plug a.
BERNINA International AG
Seestrasse 161
CH-8266 Steckborn
DRAFT – VERSION
Schweiz
Seite 57 von 172