VIGILON
INTERFACES
Our comprehensive range of Interfaces to solve all your
interfacing requirements, which are demanded by today's
systems. A keyswitch version can used for manual plant control.
The new, comprehensive range of Vigilon Interfaces have a neat
compact design casing to give maximum installation flexibility.
The range includes low voltage and mains switching variants
to meet all application needs. All variants can be installed as
either DIN rail mounted or housed in a Vigilon style enclosure. All
Interfaces are compliant with EN 54 part 18.
LOOP POWERED 4 CHANNEL
INTERFACE
The loop powered 4 channel Interface range has
individually sectored outputs where channel 1
can be set as a loop powered zone module.
Each channel can be configured as an input
Loop powered
or output independent of each other and in
4 channel Interface
accordance with the fire plan
All Interface devices can be housed in their
own neat enclosures, DIN rail mounted or
housed in a Vigilon style box
Interfaces with output channels do not require
additional relays – the panel monitors cable
faults and can raise an alarm if a fault occurs
Loop powered key
All Interfaces are seen by the panel as one
switch operated
address although each input/ output can have
Interface
a separate label displayed at the panel
MAINS POWERED INTERFACE
The Vigilon Mains Powered Interface allows you
to connect to ancillary units which can not be
integrated directly onto the Vigilon loop.
4 Channels Input or Output
24V dc Supply
24 hour battery standby
Mains powered
Fully compliant with BS7273-4
Interface
12
LOOP POWERED SINGLE CHANNEL
INTERFACE
The Vigilon System can accomodate a high
number of single channel Interfaces on the loop,
exceeding typical site requirements.
VA high capacity of single channel Interfaces is
available on the loop
Versions are available to provide inputs and
outputs to and from the system
Basic building control can be achieved
through inputs from other life safety systems
such as sprinklers and conventional fire
systems
Non fire inputs can prove current status of
systems and fault signals can be made known
through alarm outputs
Key-operated variant for secure management
of the system
LOOP POWERED MAINS SWITCHING
schools, colleges and public areas where the
INTERFACE
incidence of rogue activation may be higher
than normal
The mains switching Interfaces can switch up
Surface or flush mounted variants are available
a resistive load of up to 16amps at 240V AC
Flushes with standard installation back box
4 and single channel variants with combined
inputs and outputs make these Interfaces
An anti-vandal protective cover is available
ideal for connecting to a control plant
The glass fronted variant has a simple glass
VIGILON MANUAL CALL POINT
replacement process
The Vigilon Manual Call Point is available as a
An LED gives confirmation of operation
break glass variant or it can be supplied with a
resettable element – ideal where glass could
The Manual Call Point is EN 54 part II compliant
prove to be a safety hazard.
The Manual Call Point can be supplied as an
The Manual Call Point is available with a
IP55 rated unit
resettable element especially useful in
Loop Powered Mains
Switching Interface
Vigilon Manual
Call Point
13