Download Print this page

Operation - Sharpe Cobalt 5812L Quick Start Manual

Hvlp gravity feed spray gun, compliant gravity feed spray gun

Advertisement

COBALT GRAVITY FEED SPRAY GUN
Setup
Check that your shop air provides adequate air flow.
Use a minimum 3/8 in. ID air supply hose.
Set shop air pressure regulator (not supplied) according to
paint manufacturer's recommendation. See maximum pres-
sures and compliant air pressures on cover.
Make sure no air restrictions, such as low-volume cheater-
valves, obstruct the air flow. If an air adjusting valve is
desired, use a SHARPE Air Adjusting Valve 24AAV (part
no. 2210), 36AAV-HOV (part no. 3310) or HOV (part no.
U04410).
Install a shutoff valve (not supplied) downstream of the air
regulator to shut off gun air.
Install an inline air filter (not supplied) to clean and dry the
air supply to the gun.
1.
Make sure air supply is turned off.
2.
Connect a clean, dry, filtered air supply to the gun air inlet
(9).
3.
If this is first time using the equipment, flush the spray gun.

Operation

Pressure Relief Procedure
WARNING
Follow Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing equipment. Read
warnings, page 2.
1.
Turn off gun air supply.
2.
Trigger the gun to relieve pressure.
Flushing
WARNING
Read warnings, page 2.
Flush before using the equipment, before changing colors, and
when you are done spraying. Use solvent that is compatible with
gun wetted parts and fluid that will be sprayed. Flush at lowest
possible pressure.
Refer to Compliant Cleaning Methods, page 4, to com-
ply with air quality laws if applicable.
1.
Follow Pressure Relief Procedure.
2.
Dispose of any paint in cup.
3.
Fill cup with small amount of solvent.
4.
Spray into grounded metal waste container until equipment
is clean.
5.
Follow Pressure Relief Procedure.
F
. 1
IG
Spraying
CAUTION
Excessive atomizing air pressure can increase over-spray,
reduce transfer efficiency, result in a poor quality finish
from dry spray.
Regulatory agencies in certain states prohibit the operation
of a spray gun above 10 psi (69 kPa, .7 bar) atomizing air
cap pressure.
1.
Fill cup (20) with material. Do not fill past full markings on
cup.
2.
Turn on shop air to gun and set atomizing pressure with the
gun fully triggered.
3.
Adjust the pattern size and shape with the spray width
adjustment knob (16c). Turn knob clockwise to reduce pat-
tern size and counterclockwise to increase it.
See Troubleshooting guide if you experience an irregular
pattern.
4.
Fluid control knob (15) is factory set for maximum needle
trigger travel and material flow. To decrease needle/trigger
travel and decrease fluid flow, turn the knob clockwise.
3
20
16c
15
9
309999F

Advertisement

loading

This manual is also suitable for:

Cobalt 5814lCobalt 5816lCobalt 5815lCobalt 5818lCobalt 5823lCobalt 5712 ... Show all