Samsung AM TN4 KH Series Installation Manual page 28

Table of Contents

Advertisement

Installation Procedure
Installation options for the 02 series
SEG1
0
SEG7
1
Use of drain pump
SEG13
Use of external
2
SEG19
Individual control of a
3
remote controller
• Even if you set the Use of drain pump (SEG8) option to 0, it is automatically set to 2 (the drain pump is used with 3
minute delay).
• If you set the Maximum filter usage time (SEG18) option to a value other than 2 and 6, it is automatically set to 2
(1000 hours).
• If you set an option to a value that is out of range specified above, the option is automatically set to 0 by default.
• The SEG5 option (Use of central control) is set to 1 (Use) by default. Therefore, you don't need to set the SEG5 option
additionally. Note that even if the central control system is not connected, no errors occur. If you want a specific
indoor unit not to be controlled by the central control system, set the SEG option of that indoor unit to 0 (Disuse).
• The external output of SEG15 is generated via MIM-B14 connection. (Refer to the manual of MIM-B14.)
• If you set the Individual control with remote control (SEG20) option to a value other than 0 to 4, it is automatically set
to 0 (Indoor 1).
• The output of hot water heater in SEG9 is generated from the hot coil part of the terminal board in duct models.
COM1
(+)
Outdoor
DC 12 V Wire Remote
Communication
28
English
SEG2
SEG3
2
Evaporator Drying
SEG8
SEG9
Use of hot water
heater
SEG14
SEG15
Setting the output
of external control /
External heater signal
control
/ Cooling operation
signal / Free Cooling
control signal
SEG20
SEG21
Heating setting
compensation
/ Removing
condensate water in
heating mode
(-)
COM2
L
N
AC
HOT
Controller
POWER
COIL
SEG4
Use of external
room temperature
sensor / Minimizing
Use of central control
fan operation when
thermostat is off
SEG10
EEV Step when
-
heating stops
SEG16
Ionizer
Buzzer control
SEG22
Adjusted EEV step of
stopped unit during
Motion detect sensor
oil return /defrost
mode.
(The same as Indoor Unit's input Power)
SEG5
SEG6
FAN RPM
compensation
SEG11
SEG12
Dew removal
operation in wind
free mode
SEG17
SEG18
Hours of filter usage
SEG23
SEG24
-