Tsp3 - First Seek Check - Seagate ST8741J Maintenance Manual

Sabre disc drive
Table of Contents

Advertisement

Troubleshooting Procedures
TSP3-l
TSP3 - First Seek Check
This test assumes that the status/control panel is connected
to the drive.
001
Initiate first seek as follows:
a.
For drives with SMD or IPI interface. set
Remote/Local switch to Local.
b.
Apply power to drive.
c.
Press START switch on status/control panel.
After power up delay is completed. observe rapid
blinking of Ready indicator (indicating spindle
power up is in progress).
002
Does Ready indicator light steadily?
N
y
003
l
!rive has successfully completed first seek.
004
2-14
Is FAULT indicator on?
N
y
1
l
l
Run Diagnostic Test 04 and replace the FRU(s)
(Field Replaceable Units) indicated by the test.
1
Replace control board (proc 3302).
l
~
Replace module (proc 3204).
If problem
persists. call field support.
TROUBLE ANALYSIS
83325720 B