Vaillant ecoTEC exclusive 843 Installation And Maintenance Instructions Manual page 39

Table of Contents

Advertisement

Code
Parameter
D.034
Fan speed actual value
D.035
3-way valve position
D.036
DHW flow rate
D.039
Solar inlet temp. actual
value
D.040
Flow temperature actual
value
D.041
Return temperature actual
value
D.044
Ionisation value actual
value
D.046
Pump mode
D.047
Current outside temperat-
ure
D.050
Offset min. speed
D.051
Offset max. speed
D.052
Min. gas valve steps offset
D.058
Solar post-heating
D.060
Number of safety therm.
shut-downs
D.061
No. of shut-downs in ign.
flame controller
D.064
Avg. ignition time
D.065
Max. ignition time
D.067
Remaining anti-cycl. time
for heating
D.068
Number of first start at-
tempts
D.069
Number of second start
attempts
D.070
3-way valve operation
D.071
Max. heating target flow
temp.
D.072
Pump overrun after cylin-
der charging
D.073
Offset setting for comfort
mode
D.074
Anti-legionella funct. with
integrated cyl.
0020193968_03 ecoTEC exclusive Installation and maintenance instructions
Values
Unit
Increment, select, explanation
Min.
Max.
Current value
rpm
Current value
Position of the prioritising diverter
valve
0. Heating mode
1: Parallel operation (mid-position)
2: DHW mode
Current value
l/min
Current value
°C
Current value
°C
Current value
°C
Current value
> 800 = No flame
< 400 = Good flame
0
1
0 = Relay with disable facility
1 = PWM with disable facility
Current value
°C
(with Vaillant weather-compensated
control)
0
3000
rpm
Nominal value set in factory
-990
0
rpm
Nominal value set in factory
0
99
The offset is specified at the gas
valve assembly.
1
0
3
Only products with integrated do-
mestic hot water generation
0 = Solar post-heating deactivated
3 = Domestic hot water activated
(min. target value 60 °C)
Current value
Number of safety cut-out switch-off
sequences
Current value
Current value
s
Current value
s
Current value
min
Current value
Unsuccessful ignitions at 1st at-
tempt
Current value
Unsuccessful ignitions at 2nd at-
tempt
0
2
0 = Normal operating mode
1 = Mid-position (parallel operation)
2 = Permanent heating position
40
80
°C
Target value maximum heating flow
temperature
1
0
10
min
Internal pump
1
−15
5
K
Only products with integrated do-
mestic hot water generation
1
0
1
0: Off
1: On
Appendix
Default
Own
setting
setting
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
0
Not ad-
justable
0
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
0
75
2
0
1
39