Advertisement

Quick Links

Operating Instructions
Digital Blood Pressure Monitor
EW-BU18W011
Model NO.
Thank you for purchasing our products.
Please read these in structions carefully before using
Version: NO.01.1
this product, and save this manual for future use.
1
Issued date: March 2023

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic EW-BU18W011

  • Page 1 Operating Instructions Digital Blood Pressure Monitor EW-BU18W011 Model NO. Thank you for purchasing our products. Please read these in structions carefully before using Version: NO.01.1 this product, and save this manual for future use. Issued date: March 2023...
  • Page 2: Table Of Contents

    • Specifications • About each instruction Product name: Digital Blood Pressure Monitor Model: EW-BU18W011 Structure and composition: It is composed of a main unit and a cuff Scope of application: This product can measure diastolic blood pressure, systolic blood pressure and pulse rate of human body by oscillometry, and its values are for diagnostic reference.
  • Page 3: How To Take A Proper Measurement

    How to take a proper measurement Relax for 4~5 minutes before measurement and be sure to take the measurement in a relaxed state. The posture and physical condition of the user will affect the blood pressure measurement. Wrap the Measuring posture Align the height cuff around of the cuff to...
  • Page 4: Product Functions

    Product functions: Please confirm the function of purchased product EW-BU18W011 Hypertension flash ● Memory number 90 times×1 person Movement warning ● Irregular pulse ● Morning and evening comparison — Clock function — APP client — Voice function — Backlight function —...
  • Page 5 For safety reasons, be sure to observe these safety precautions. indicates the contents of caution and warning. WARNING indicates a hazardous situation whih, if WARNING: not avoided, could result in death or serious injury. CAUTION indicates a hazardous situation which, if CAUTION: not avoide,could result in minor or moderate injury.
  • Page 6 Be sure to please contact the After-sales Service Office designated observe by Panasonic Appliances (China) Co., Ltd. to consult the maintenance methods or ask for maintenance information. Caution: If the device needs to be repaired for various reasons, please contact the After-sales...
  • Page 7 Please note that ※During the measurement process, do not use devices that generate electromagnetic interference near this product, such as mobile phones, as the strong radiation field generated by such devices will interfere with the normal use of the product. Otherwise, this product may cause mis-operation or inaccurate measurement.
  • Page 8: Parts Identification

    Parts identification Structure and composition: Main unit The product is composed of a main unit and a cuff. Please confirm Note: All diagrams in this specification are for EW-BU18W011 the product Display Cuff socket Bottom Battery cover Memory /Recall button...
  • Page 9 Parts identification Cuff Cuff plug Tube Velcro fastener Includes Memory mark When the measured value is stored, this mark will flash Memory number Systolic blood pressure Indicates the systolic Pulse mark blood pressure value Indication of the detected pulse during measurement Diastolic blood pressure Battery indicator...
  • Page 10: Preparation

    Batteries last for approx. 300 times, which is 3 times/day for 3 months (when using a pack of new Panasonic zinc carbon batteries). (Under the condition that the room temperature is 23 °C, 22.7 kpa (170 mmHg) pressured, and the circumference of upper arm is 30cm.)
  • Page 11: Power-On Prompt

    Preparation Power-on prompt Power-on prompt Note: When the product is under standby mode, “0” will be displayed on the monitor. This is a normal condition, not malfunction. Preparation Before measurement For correct measurement, please read the following key points carefully, and observe the exact environment and posture.
  • Page 12 Preparation Before measurement It is closest to the blood pressure at night and basically with no Within 1 hour Within 1 hour after getting up after getting up influence due to physical activities. •Before breakfast •Before taking medicine (in case of antihypertensive drugs, etc.) •After urination •Relax for 4~5 mins The measured value is closest to the average blood pressure...
  • Page 13 Preparation Before measurement Posture Method of cuff wrapping Do not lean forward Do not wrap the cuff on your clothes When the abdomen is stressed, the blood The pressure of the cuff pressure will rise. cannot be transmitted to the blood vessels and the blood pressure will rise.
  • Page 14: Wrapping The Cuff

    Preparation Wrapping the cuff ※Be sure to use a dedicated cuff It can be wrapped on either left or right arm for measurement. Take the measurement of left arm as an example. The measurement results of the left and right arms may vary to different extent due to different conditions of each user.
  • Page 15 Preparation Wrapping the cuff Hold down the hook and loop fastener and wrap the cuff with a gap of 1 or 2 fingers. Velcro fastener Velcro fastener If it is wrapped too loose, the cuff will swell and inflate, and the blood vessel will be locally tightened, which will cause an indication error, and the measured value will tend to rise slightly.
  • Page 16: Operating Instructions

    Operating instructions Start measurement With the power off, press the button. After the display is fully lit, the cuff will be pressurized and measurement will be taken automatically Note: When the pressurization value is more than 280 mmHg, the cuff will automatically exhaust.
  • Page 17 Operating instructions Start measurement Press the button to store the measured value. SYS. DIA. Press the button and Pulse take off the cuff. /min Press the button for about 5 seconds, to switch measuring methods of mmHg and kPa. It is mmHg by factory setting.
  • Page 18 Operating instruction Call-up and deletion of measured values Call-up of measured values Call up the recorded measured values for confirmation When the power is turned off, you can directly press button to call up the latest measured value. Press the button again to display the previous measured value.
  • Page 19: About Each Instruction

    Operating instruction About each indication As the basis of correct measurement, there are movement warning and irregular pulse warning. After the signal is displayed, the correct measured value may not be obtained. After the measurement, re-measurement is recommended. (Please rest for 4~5 mins before re-measurement) The measured values of each signal are also recorded together.
  • Page 20 Reading of [Blood Pressure Indication] For the Systolic • Diastolic Blood Pressure value, the WHO/ISH (World Health Organization/International Society of Hypertension) blood pressure classification table shall be used as a benchmark to judge whether it is within the hypertension range or a normal range. If it is within the hypertension range, the measured value will flash.
  • Page 21: Others

    Others Storage Pull the cuff plug out of Click the cuff socket. Store the cuff. ① Place the tube into the cuff. • Please do not stretch or bend the tube with force and do not roll the tube around the main unit. (Otherwise, it will cause malfunction) Velcro...
  • Page 22: Care And Maintenance

    Others Care and maintenance Cleaning frequency/maintenance cycle 1. Cleaning of main unit Visually confirm the appearance of the main unit. If there is dirt, for cleaning, please turn off the power supply and gently wipe it with cloth that is soaked in soapy water or warm water then wrung.
  • Page 23: Faq

    Others Questions Answers Why does the • Whether the cuff is properly wrapped. → Whether the cuff is too loose or too tight. systolic or → Whether the cuff is wrapped to the upper arm. diastolic blood (Refer to P14 for the correct wrapping method) pressure value •...
  • Page 24 Others Questions Answers When the hand The so-called [ ] warning means that during the measurement process, the device will give a movement or the wrist is warning when the cuff senses excess pressure due to moved, but the the movement of the arm, etc. ] mark is Therefore, the [ ] warning may not be displayed...
  • Page 25: Troubleshooting

    Others Troubleshooting Please confirm before consulting or repairing Failures Cause and solution polarities of the batteries are installed Even if the incorrectly. Please refer to P10 button is pressed, Battery power is low. Please refer to P10 there is no display The button pressing time is not sufficient.
  • Page 26 Others In case of abnormality Failures Cause and solution Low battery. Please refer to P10 Pressurization to more than 280 mmHg. Is the measurement posture correct? (P3,P13) Pressure decreased suddenly. Is the measurement method and posture correct? (P3,P13) Is the cuff wrapped correctly? (P14) Is the cuff plug inserted correctly? (P15) Please relax for 4~5 mins.
  • Page 27: Specifications

    Others Specifications Power supply 4 AA zinc carbon or alkaline batteries Display Digital LCD Method of Oscillographic system measurement Static pressure measurement range: (0.0~37.3) kPa ((0 ~ 280) mmHg) Pulse measurement range: (30~160) beats/min Measurement Blood pressure measurement range: systolic blood pressure shall range meet at least (8.0~30.7) kPa ((60 ~ 230) mmHg);...
  • Page 28 ※If stored and used outside the specified temperature and humidity range, the specified performance specifications may not be met. ※Product specifications are subject to change without further notice. Panasonic Appliances (China)Co., Ltd ©Panasonic Appliances (China)Co., Ltd Issued date: 2023.3.1 Printed in China...

Table of Contents