Summary of Contents for Siemens MAMMOMAT 3000 Opdima

  • Page 1 Service Workstation © Siem ens A G 1 999 The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model _or_ design,_are_...
  • Page 2 MAMMOMAT 3000 Opdima Register 5 SPB7-203.061.02 Page 2 of 4 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...
  • Page 3 Monitor Mode ........3 - 2 Siemens-Elema AB Register 5 SPB7-230.061.02 Page 3 of 4 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD...
  • Page 4 Installing the Mouse ....... . 5 - 6 MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02...
  • Page 5 64 30 453. The workstation consists of the main components • - Hard Disk Drive - Camera Interface - Serial Interface • • Siemens-Elema AB Register 5 SPB7-230.061.02 Page 1 of 6 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 6 There are no more tools required than the below numbered unless otherwise noted. • anti-static wristband and grounded tabletop pad (TDK equipment Type 8005 from 3M Deutschland GmbH). • screwdriver • Phillips screwdriver MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 2 of 6 Siemens-Elema AB Service Rev. 02 05.99...
  • Page 7 Select "shutdown" in the "login" dialogue. NOTICE The power is turned off automatically when shutdown is selected. Top Cover Fig. 2 Removing the top cover Siemens-Elema AB Register 5 SPB7-230.061.02 Page 3 of 6 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 8 Monitor Interface Serial Line B (Biopsy Contr. X204) Keyboard Interface SCSI Interface <...> SCSI Interface Tab. 1 Rear Side of the Ultra 1 with all Interfaces MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 4 of 6 Siemens-Elema AB Service Rev. 02 05.99...
  • Page 9 Hold the sides of the cover and lift it from the back panel. When the cover clears the back panel, move the cover away from the front panel to free it from the chassis. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 5 of 6 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 10 This page intentionally left blank. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 6 of 6 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...
  • Page 11 Loosen all four screws form the back of the box (refer to Fig. 2). Screws C and D secure the CPU to the back plate of the box. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 1 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 12 Power Supply SBUS Memory, SIMM SCSI Disk 0 SPARC CPU Ultra 1 Fig. 3 Connectors on the Ultra 1 OPD00276 FRONT MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 2 of 20 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...
  • Page 13 Remove the Frame Buffer (refer to the chapter "Replacing the Frame Buffer"). • On the new CPU board, install the previously removed NVRAM and the memory modules. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 3 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 14 • Mount the top cover of the box (refer to chapter 1). • Switch on the system. • Ensure that the system is operating properly. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 4 of 20 Siemens-Elema AB Service Rev. 02 05.99...
  • Page 15 Remove the frame buffer board and place it on the grounded tabletop pad. • Locate the NVRAM and remove the NVRAM from the board (refer to Fig. 5). Siemens-Elema AB Register 5 SPB7-230.061.02 Page 5 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 16 Change the parameter values of the NVRAM to the correct values. • Replace the old Internet address with the new one. • Replace the old CPU no. with the new one. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 6 of 20 Siemens-Elema AB Service Rev.
  • Page 17 Siemens-Elema AB Register 5 SPB7-230.061.02 Page 7 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 18 Read these instructions completely prior to beginning the replacement. Follow all procedures for removing and installing the DSIMM. Follow all general safety guidelines when replacing the DSIMM. Note the special safety guidelines indicated in these instructions. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 8 of 20...
  • Page 19 Fig. 7). • Release the module from the socket and place it on a grounded tabletop pad. Fig. 7 SIMM retainers Siemens-Elema AB Register 5 SPB7-230.061.02 Page 9 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 20 Switch on power to the system. • Ensure that the system is functioning properly. • After the reset the system should show up with: "64 MB Memory installed". MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 10 of 20 Siemens-Elema AB Service Rev.
  • Page 21 Sun Ultra 1 UPA / SBus (Ultra SPARC 143 MHz), Keyboard Present Open Boot 3.3, 64 MB Memory installed, Serial#..Ethernet address 8:.., Host ID:..Fig. 9 System Message Siemens-Elema AB Register 5 SPB7-230.061.02 Page 11 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 22 FRONT Fig. 10 Location of Camera Interface D100 Read these instructions completely prior to beginning the replacement. Follow all procedures for removing and installing the Camera Interface D100. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 12 of 20 Siemens-Elema AB Service Rev.
  • Page 23 • Remove the board and place it on the grounded tabletop pad. Fig. 11 Card retainers Siemens-Elema AB Register 5 SPB7-230.061.02 Page 13 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 24: Test Points

    Switch on power to the system. • You may check the 5 V power on the test points (refer to Fig. 16). • Ensure that the system is operating properly. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 14 of 20 Siemens-Elema AB Service Rev.
  • Page 25 CIA card is a credit-card-sized, removable module that has become the expansion vehicle for (portable) computers. In the OPDIMA system the PCMCIA Interface is used for the connection to a MODEM. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 15 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 26 Carefully lift the corners of the board to release it from the connector • Remove the board and place it on the grounded tabletop pad. Fig. 14 Card retainers MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 16 of 20 Siemens-Elema AB Service Rev. 02 05.99...
  • Page 27: Eject Button

    Eject button Fig. 15 PCMCIA Interface • Switch on power to the system. • Ensure that the system is operating properly. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 17 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 28 Follow all procedures for removing and installing the Frame Buffer board. Follow all general safety guidelines when replacing the Frame Buffer. Note the special safety guidelines indicated in these instructions. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 18 of 20...
  • Page 29 Insert the new Frame Buffer carefully in the original location. • Check the jumpers of the frame buffer (refer to Fig. 17). Fig. 17 Jumper Setting Frame Buffer Siemens-Elema AB Register 5 SPB7-230.061.02 Page 19 of 20 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 30 • Switch on power to the system. • Ensure that the system is operating properly. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 20 of 20 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...
  • Page 31 SCSI ID. Distribution Disk SCSI ID CD-drive CD-drive installed when SW-upgrade Data Disk SCSI ID MO-drive Fig. 1 Disk System Siemens-Elema AB Register 5 SPB7-230.061.02 Page 1 of 10 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 32 To detect a faulty device enter ok probe-scsi Fig. 2 Test of the SCSI bus The system should show all the drives connected to the bus: MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 2 of 10 Siemens-Elema AB Service Rev.
  • Page 33 Swing the plastic latch to the left and slide the disk drive support and disk drive outward on the guide rails and remove it from the box. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 3 of 10 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 34 • Swing the plastic latch to the left and Side View OPENER MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 4 of 10 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...
  • Page 35 * CD ROM Disk Drive is installed when SW upgrade shall be performed. System Disk SCSI ID Seagate ST32550WC J2 connector Pin 1 J4 connector SCSI ID = 0 Pin 1 Siemens-Elema AB Register 5 SPB7-230.061.02 Page 5 of 10 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 36 The system should show all the drives connected to the bus (refer to Fig. 3). • If the disk drives shows up correctly load the software (refer to chapter "Loading the System Software"). See MAMMOMAT 3000 Opdima™ Digital Biopsy and Spot Imaging System - Service Instructions (SPB7-230.061.03..) MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02...
  • Page 37: Remove The Unit

    (refer to Fig. 10). • Unplug the SCSI terminator from the back of the unit (refer to Fig. 10). • Remove the unit. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 7 of 10 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 38 * CD ROM Disk Drive is installed when SW upgrade shall be performed. In/Out SCSI SCSI ID Switch Device Mode Switch connectors AC in ON/OFF switch Fig. 9 MO System, back view MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 8 of 10 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD...
  • Page 39: Scsi Terminator

    SCSI terminator Fig. 10 Archive System SCSI ID Switches • Switch on the system. • Ensure that the system is operating properly. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 9 of 10 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 40 This page intentionally left blank. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 10 of 10 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...
  • Page 41 Disconnect the power supply cable from the back of the box. • Loosen the screw that secures the power supply (refer to 1, Fig. 1). Siemens-Elema AB Register 5 SPB7-230.061.02 Page 1 of 4 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 42 Plug 2 Plug 3 Fig. 3 Power Supply Connector • Move the power supply a few millimeters to the left side to release it from the bottom. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 2 of 4 Siemens-Elema AB Service Rev.
  • Page 43 Connect the power supply cable to the back of the box. • Switch on the system. • Ensure that the system is operating properly. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 3 of 4 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 44 This page intentionally left blank. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 4 of 4 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...
  • Page 45 Note the special safety guidelines indicated in these instructions. The entire system should be switched off when the monitor is being replaced. NOTICE Fig. 2 Symbol Siemens-Elema AB Register 5 SPB7-230.061.02 Page 1 of 6 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 46 Rear Side of the box, Monitor Interface • Remove the monitor. Install the monitor by reversing the order in which it was removed. • Ensure that the system is operating properly. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 2 of 6 Siemens-Elema AB Service Rev.
  • Page 47 Keyboard Interface Fig. 4 Back of the box (without D100). CAUTION • Remove the keyboard connector in back of the box. Siemens-Elema AB Register 5 SPB7-230.061.02 Page 3 of 6 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 48 NOTICE • Remove keyboard with cable. Install the new keyboard by reversing the order in which it was removed. • Ensure that the system is operating properly. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 4 of 6 Siemens-Elema AB Service Rev.
  • Page 49 The entire system should be switched off when parts are being replaced. CAUTION • Remove the mouse with the cable (refer to Fig. 6). Siemens-Elema AB Register 5 SPB7-230.061.02 Page 5 of 6 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 50 Install the new mouse by reversing the order in which it was removed. Fig. 6 Rear view of the keyboard: Installing the mouse • Ensure that the system is operating properly. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 6 of 6...
  • Page 51 System Disk........3 - 3 System Software......3 - 6 top cover .......... 2 - 1 Ultra 1 ........2 - 1, 2 - 3 Siemens-Elema AB Register 5 SPB7-230.061.02 Page 1 of 2 MAMMOMAT 3000 Opdima Solna, Sweden Rev. 02 05.99 SPS-UD Service...
  • Page 52 This page intentionally left blank. MAMMOMAT 3000 Opdima Register 5 SPB7-230.061.02 Page 2 of 2 Siemens-Elema AB Service Rev. 02 05.99 SPS-UD Solna, Sweden...