Wall Mounted Type (Fdkn) - Mitsubishi Heavy Industries FDTVA402HEN1R Technical Manual

Table of Contents

Advertisement

(3) Wall mounted type (FDKN)

(a) Twin type
Model FDKNVA402HENP1R (Indoor unit: 2 units, Outdoor unit: 1 unit)
Item
Nominal cooling capacity
(1)
Nominal heating capacity
(1)
Power source
Cooling power consumption
Running current (Cooling)
Power factor (Cooling)
Heating power consumption
Running current (Heating)
Power factor (Heating)
Inrush current (L.R.A)
Noise level
Exterior dimensions
Height × Width × Depth
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
Quantity
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Starting method
Air flow
Outside air intake
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Safety equipment
Installation data
Refrigerant piping size
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Notes (1) The data are measured at the following conditions.
Operation
Cooling
Heating
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard. ISO-T1 "UNITARY AIR-CONDITIONERS"
(3) The operation data indicate when the air-conditioner is operated at 230V 50Hz.
(4) Values in [ ~
(5) Indoor unit specifications show the specifications for one unit. Capacity and running characteristics values are shown for the case where two indoor units
are combined and run together.
(6) If wireless specifications are used, use 1 wireless indoor unit in combination with wired indoor units.
Model
kW
kW
kW
A
%
kW
A
%
A
dB(A)
mm
kg
kW
kg
r
W
Powerful mode Hi:13 Me:12 Lo:11
CMM
W
Wireless remote control switch (Optional: RCN-E1R)
Wired remote control switch (Optional: RC-E1R)
Liquid line
mm
Gas line
(in)
Connectable with VP16 (I.D.16mm, O.D.22mm)
Item
Indoor air temperature
DB
27˚C
20˚C
] show the minimum to maximum range.
FDKNVA402HENP1R
FDKNA201R
1 Phase, 220/230/240V, 50Hz
Powerful mode Hi:47 Me:44 Lo:41
Mild mode Hi:44 Me:41 Lo:38
298 × 840 × 240
12
Slitted fin & inner grooved tubing
Microcomputer controlled de-icer
Tangential fan × 1
33 × 1
Direct line start
Mild mode Hi:12 Me:11 Lo:9
Unavailable
Long life filter ×2(washable)
Rubber sleeve (for fan motor)
Thermostat by electronics
Internal thermostat for fan motor.
Frost protection thermostat.
Indoor branch pipe, Outdoor main pipe: φ9.52 (3/8")
Indoor branch pipe: φ12.7 (1/2"), Outdoor main pipe: φ15.88 (5/8")
Necessary (both Liquid & Gas lines)
Mounting kit. Drain hose
Outdoor air temperature
WB
DB
19˚C
35˚C
7˚C
28
-
-
FDCVA402HENR
10.0 [6.1~11.2]
11.2 [5.6~12.5]
2.90
12.8
99
3.24
14.2
99
5
50
845 × 970 × 370
63
RM-B5125MD11
2.4
Direct line start
Straight fin & inner grooved tubing
Electronic expansion valve
R410A
3.8 [Pre-charged up to the piping length of 30m]
0.7 (M-MA68)
Propeller fan × 1
120 × 1
Direct line start
Cooling: 75, Heating: 73
Rubber mount (for compressor)
20 (Crank case heater)
– (Indoor unit side)
Internal thermostat for fan motor.
Abnormal discharge temperature protection.
Flare piping
WB
24˚C
6˚C
Standards
ISO-T1