4-5.
RETURN VIDEO Cable Compensation
System Adjustment
4-5-1.
Return Video Carrier Frequency
Adjustment
Equipment
: Spectrum analyzer
To be extended
: CT-181 board
Preparation :
* Input 10 STEP signal (sub-carrier : OFF) of video signal
generator to RETURN-I connector (75 Q termination, 1.0
V p-p) on the CCU-TX7/TX7P rear panel.
Test point
: TP21 (GND: E12)/CT-181 board
Adjusting point : @CV1 (RET FREQ)/CT-181 board ~
Specification
—: 69.000 +0.005 MHz
SYNC
69.0MHz
CENT FREQ: 69.0MHz
FFEQ SPAN: 5.0MHz
OEt001
g
E12@@2
RF AGCOLY
o2
=
Av22
a -
4-5-2.
Return Video Deviation Adjustment
Equipment
: Spectrum analyzer
To be extended
: CT-181 board
Preparation :
* Input 10 STEP signal (sub-carrier : OFF) of video signal
generator to RETURN-1 connector (75 Q termination, 1.0
V p-p) on the CCU-TX7/TX7P rear panel.
Test point
: TP21 (GND: E12)/CT-181 board
Adjusting point : @RV20 (RET DEV)/CT-181 board
Specification
:T=2.000 0.005 MHz
T
69.0MHz
CENT FREQ: 69.0MHz
FFEQ SPAN: 5.0MHz
Note : Performe the adjustment of 4-5-1. "Return Video
Carrier Frequency Adjustment" when the SYNC
portion is moved during the adjustment.
PROMPT FREQ
pat
4,
Av23
PROMPT LEVEL
eRoMey Fun:
WS 02
E18OTP220 [0 Jenomer se rx
2
L_ Jrrcmet
Bo fo] &
sroog
OK
Ne
C71 Seoero
paer
IF BOARD
TP1001
wo OP AD
TP2003 TP2002
TP2004
TP2001
TP2005
°
CCU-TX7 (E)\V1
CT-181 Board (A SIDE)
4-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ccu-tx7pCou-tx7Dxbk-701

Table of Contents