4-4-8.
R-Y Crosstalk Adjustment
4-4-9.
R-Y OUT Level Adjustment
Note : Make sure that 45 MHz frequency on the YM-15
Equipment
: Oscilloscope
board (CA-TX7/TX7P) is correct.
To be extended
: YD-26 board
Preparation :
Equipment
: Oscilloscope
* S4 (C 2nd AGCY/YD-26 board > "ON"
To be extended
: YD-26 board
Test point
: TP19 (GND: E9)/YD-26 board
Test point
: TP19 (GND: E9)/YD-26 board
Adjusting point : @RV17 (R-Y LEVEL)/YD-26 board
Adjusting point : @RV18 (90° SETVYD-26 board
Specification
:A=350+5mV
Specification
:The SAMPLE pulse level should be
minimum.
A=02+3mV
|
A
Ra
Vv
4-22