Information About Remote Control By Pilot Wire - Supra Dalbeo Presence 1022 Installation And Operating Instructions Manual

Electric radiator with mineral oil with 7 day programme, open window detection, gauge and energy consumption indication and pin code lock
Table of Contents

Advertisement

Operating
Setting
temperature
19°C
18°C
17.5°C
17°C
7°C
Comfort
-1°C
-1.5°C
20min
40min
60min
Unoccupancy detected
I
NFORMATION ABOUT REMOTE CONTROL BY PILOT WIRE
Overview
Your device can be controlled by a central control unit through a pilot wire, in which case the different operating modes will be remotely enabled by the
programmer.
You can only control the device by pilot wire in the Auto mode. In the other modes, the orders transmitted by the pilot wire will not be executed.
In general, a pilot wire control system makes it possible to impose externally a lowering of the temperature setpoint, combined with the internal pro-
gramming and the occupancy detection.
If several lowering requests appear simultaneously, priority is given to the lowest temperature setpoint, thus maximising savings
priorities for different modes on page
When a signal is sent from the pilot wire, the self learning optimisation function is suspended.
Below are the different views of the display for each order sent by pilot wire:
Pilot wire = Comfort
Pilot wire = Eco - 2
Comfort - 2°C
-2°C
Frost
protection
72h
Occupancy detected
19).
Pilot wire = Eco
Comfort - 3,5°C
Pilot wire = Frost protection
Divisions of the detection zone
Detection zone, for a temperature of 19°C.
Top view
Comfort
Hours
Side view
18
The detection zone is
divided into active and
inactive areas. A person
that crosses the area
will be detected by the
Active area
infrared sensor.
Inactive area
(see information on
Pilot wire = Eco - 1
Comfort - 1°C
Pilot wire = Stop (Standby mode)
FR9011450-60-70B-0322