- Objects moving with the wind like curtains and plants.
Disable the occupancy detection if your radiator was installed near of
these.
To disable the occupancy detection,
Note: the detection range varies depending on the ambient temperature.
• Overview
Dalbeo Wi-Control fits your lifestyle
while keeping your power consump-
tion under control.
With its front infrared sensor, Dalbeo
Wi-Control optimises the management
of heating: it detects movement in the
room where it is installed and in case
of absence, automatically performs
a progressive lowering of the setting
temperature
resulting
in:
savings. To ensure proper operation, do
not block the sensor's field of view by any obstacle (curtains, furnitures ...).
Unoccupied periods *
20 minutes
40 minutes
1 hour
72 hours
* Unchangeable factory settings
Note: when presence is detected in the room, the device automatically
returns to the initial mode.
Remarks: by default, when the sensor is enabled and detects movement
in the room, the display lights up for a few seconds and then turns off. To
delete the backlight when occupancy is detected,
tings - Backlight settings.
• Operating
Example of reduction with a Comfort setpoint temperature of 19°C.
Setting
temperature
19°C
18°C
17.5°C
17°C
7°C
Comfort
-1°C
-1.5°C
20min
40min
60min
Unoccupancy detected
• Divisions of the detection zone
Top view
Active area
Inactive area
see page 20.
energy
Lowering setting temperature*
Comfort -1°C
Comfort -1,5°C
Comfort -2°C
Frost protection
see page
17, user set-
-2°C
Frost
Comfort
protection
72h
Occupancy detected
Detection zone, for an ambi-
ent temperature of 19°C.
The detection zone is divided
into active and inactive areas.
A person that crosses the area
will be detected by the infrared
sensor.
I
NFORMATION ABOUT REMOTE
CONTROL BY PILOT WIRE
• Overview
Your heating device can be controlled by a central control unit through a
pilot wire, in which case the different operating modes will be remotely
enabled by the programmer.
You can only control the device by pilot wire in the Auto mode. In the other
modes, the orders transmitted by the pilot wire will not be executed.
In general, a pilot wire control system makes it possible to impose externally
a lowering of the temperature setpoint, combined with the internal
programming and the occupancy detection.
If several lowering requests appear simultaneously, priority is given to the
lowest temperature setpoint, thus maximizing savings
priorities for different modes
When a signal is sent from the pilot wire, the self-learning optimisation
function is suspended.
Below the different views of the display for each order sent by pilot wire:
Examples with a Comfort setpoint temperature of 19°C
Pilot wire = Comfort
Hours
Pilot wire = Eco - 1
Comfort - 1°C
Pilot wire = Frost protection
7°C
16
(see information on
beside).
Pilot wire = Eco
Comfort -3.5°C
Pilot wire = Eco - 2
Comfort - 2°C
Pilot wire = Stop (Heating
standby mode)
FR9011480-90-500B-03-22
Side view

Advertisement

Table of Contents
loading