Intermatic ETW2CP Installation And Setup Instructions
Intermatic ETW2CP Installation And Setup Instructions

Intermatic ETW2CP Installation And Setup Instructions

Intermatic connect 365-day programmable smart wi-fi timer
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

MODELS: ETW2CP, ETW3CP
Installation and Setup Instructions
WARNING
Risk of Fire or Electric Shock
• Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
• More than one circuit breaker or disconnect switch may be required to de-energize the equipment before servicing.
• For plastic enclosures, bonding between conduit connections is not automatic and must be provided as part of the installation.
• Installation and/or wiring must be in accordance with National and Local Electrical Code requirements.
• Use #14-#8 AWG wires, rated at least 105° C - COPPER conductors ONLY.
• If the power disconnect point is out of sight, lock it in the OFF position and tag it to prevent unexpected application power.
• Make sure there is no wire insulation under the terminal plate on the time switch connector. Firmly tighten terminal screws.
• For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for fitting conduit
and outlet boxes) are to be used.
• Do NOT exceed maximum current carrying capacity.
• KEEP DOOR CLOSED AT ALL TIMES when not servicing.
NOTICE
• Do NOT touch circuit board components, contact can create a static discharge, which can damage these electronic components.
Description
Intermatic ETW2CP and ETW3CP Smart Timers offer a multi-
purpose solution for indoor and outdoor load control
applications. Available in a 2-circuit and 3-circuit configuration,
these controls provide flexible 365-day, Astronomic, and
Holiday programming options.
Once onboarded to a wireless network, the ETW2CP/ETW3CP
can be controlled using the Intermatic Connect app, available
via Google Play and the App Store. Units can be field
configured for either single-pole or double-pole applications
and be used for 120-277 VAC. The controls also include
terminal locations for line voltage overrides.
Federal Communications Commission (FCC) Notice for ETW Series Wi-Fi Timers
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference, including interference that may cause undesired operation. This equipment
has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses and radiates radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference
to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference that requires the user to correct
at his or her own expense.
ETW3CP
Intermatic Connect 365-Day
Programmable Smart Wi-Fi Timer
Ratings
Electrical Specifications
Operating Voltage
Remote Inputs
Load Rating (Motor)
FLA
Power Consumption
Electronic Ballast
General Purpose
Current Rating
Impulse Voltage
Overvoltage Category
Pollution Degree
Operating Temperature
Control Construction
Enclosure Type
Dimensions H x W x D
120-277 VAC, 50/60 Hz
120-277 VAC, 50/60 Hz
1 HP 120 VAC (NO)
2 HP 240 VAC (NO)
16 A FLA, 96 A LRA, Type 1C @ 120 VAC 50/60 Hz (NO)
15 A FLA, 96 A LRA, Type 1C @ 240 VAC 50/60 Hz (NO)
7 W
16 A per circuit (NO)
30 A (NO)
10 A (NC) @ 55° C, 5 A (NC) @ 70° C
4000 VAC
III
3
-40º C to 70º C
Independently Mounted
Type 3 Indoor/Outdoor Enclosure
7 1/2" x 8 7/8" x 3"

Advertisement

Table of Contents
loading

Summary of Contents for Intermatic ETW2CP

  • Page 1 ETW3CP Power Consumption Description Electronic Ballast 16 A per circuit (NO) Intermatic ETW2CP and ETW3CP Smart Timers offer a multi- General Purpose 30 A (NO) Current Rating purpose solution for indoor and outdoor load control 10 A (NC) @ 55° C, 5 A (NC) @ 70° C applications.
  • Page 2: Installation

    Apply power to the time switch. 10. Install ¼” Padlock thru hasp to secure if desired. (lock not included) 11. Device configuration are done using the Intermatic Connect mobile app. (available via the App Store and Google Play) Wiring Diagrams...
  • Page 3: Additional Information

    1 second off for the duration of the override. Additional Information Online Programming Schedule Guide Intermatic Connect App Scan this qr code to access Scan this qr code to download the ETW2CP, ETW3CP the Intermatic Connect App via Programming Schedule Guide the App Store and Google Play...
  • Page 4 This Page Intentionally Left Blank...
  • Page 5 4000 VCA opciones de programación flexibles de 365 días, astronómicas y de días festivos. Categoría de sobretensión Una vez integrados en una red inalámbrica, los ETW2CP/ Grado de contaminación ETW3CP pueden ser controlados mediante la aplicación Temperatura de funcionamiento -40 °C a 70 °C Intermatic Connect, disponible en Google Play y App Store.
  • Page 6: Instalación

    10. Instale un candado de ¼" a través del pasador para asegurarlo si lo desea (candado no incluido). 11. La configuración del dispositivo se realiza mediante la aplicación móvil Intermatic Connect (disponible en App Store y Google Play). Diagramas de cableado Figura A: 3 Circuitos: 3xSPDT o 1xDPDT+1xSPDT, el Circuito 1 y el Circuito 2 se pueden emparejar para aplicaciones DPDT.
  • Page 7: Información Adicional

    Guía de programación en línea Aplicación Intermatic Connect Escanee este código qr para Escanee este código qr para acceder a la Guía de descargar la aplicación Programación ETW2CP y Intermatic Connect a través de ETW3CP App Store y Google Play...
  • Page 8 This Page Intentionally Left Blank...
  • Page 9 365 jours, 4000 V CA astronomiques et jours fériés. Catégorie de surtension Une fois connecté à un réseau sans fil, le ETW2CP/ETW3CP peut Degré de pollution être contrôlé à partir de l’application Intermatic Connect, Température de fonctionnement -40º C à...
  • Page 10: Schémas De Câblage

    10. Installez un cadenas de ¼ po à travers le moraillon pour le fixer si vous le souhaitez. (verrou non inclus) 11. La configuration du dispositif est réalisée à l’aide de l’application mobile Intermatic Connect. (disponible sur App Store et Google Play) Schémas de câblage...
  • Page 11 Clignement Renseignements complémentaires Guide de programmation en ligne Application Intermatic Connect Numérisez ce code QR pour Numérisez ce code QR pour accéder au guide de télécharger l’application programmation du ETW2CP, Intermatic Connect App sur App ETW3CP Store et Google Play...
  • Page 12 El servicio de garantía está disponible mediante (a) la devolución del producto al proveedor al que se le compró la unidad; o (b) el llenado de un reclamo de garantía en línea en www.intermatic.com. Esta garantía está hecha por: Intermatic Incorporated, Customer Service 1950 Innovation Way, Suite 300, Libertyville, IL 60048.

This manual is also suitable for:

Etw3cp

Table of Contents