1. SPECIFICATIONS
Service Ref.
Indoor type
1
Capacity Rated*
1
Rated power consumption*
Current input (208/230V)
EER2
SEER2
1
Capacity Rated 47°F*
2
Capacity Max. 17°F*
Capacity Max. 5°F
Rated power consumption 47°F*
Current input (208/230V)
1
COP 47°F*
HSPF2
Power supply
Breaker Size/Maximum over current protection
Minimum circuit ampacity
Indoor unit
Total capacity
connectable
3
Model/Quantity *
Sound pressure level
(measured in anechoic room)
Refrigerant
Liquid pipe
piping diameter
Gas pipe
Fan
Type × Quantity
ow rate
Control, Driving mechanism
Motor output
External static press.
Compressor
Type × Quantity
Manufacture
Starting method
Motor output
Case heater
Lubricant
External nish
External dimension H × W × D
Protection
High pressure protection
devices
Inverter circuit (COMP./FAN)
Compressor protection
Fan motor protection
Refrigerant
Type x original charge
Control
Net weight
Heat exchanger
HIC circuit (HIC: Heat Inter-Changer)
Defrosting method
Guaranteed operation range
Remarks
* 1 Rating conditions
Cooling Indoor
Outdoor : D.B. 95°F [D.B. 35.0°C]
Heating Indoor
Outdoor : D.B. 47°F/W.B. 43°F [D.B. 8.3°C/W.B. 6.1°C]
* 2 Conditions
Heating Indoor
Outdoor : D.B. 17°F/W
*3 It cannot be connected mixed CITY MULTI indoor unit and branch box indoor unit.
*4 D.B. 5 to 115°F [D.B. -15 to 46°C], when an optional Air Outlet Guide is installed.
However, this condition does not apply to the indoor units listed in *5.
*5 50 to 115°F (10 to 46°C)D.B.: When connecting PKFY-P04/06/08/12NLMU, PFFY-P06/08/12NEMU, and PFFY-P06/08/12NRMU type indoor unit.
*6 When the temperature is below D.B. 50°F [D.B. 10°C] with branch box system, noise could potentially occur.
M-P0890
MXZ-SM36NAMHZ2-U1
Non-Ducted
Mix
Btu/h
36,000
36,000
W
2,400
2,670
A
11.7/10.6
13.0/11.8
Btu/h/W
15.0
13.5
-
23.0
20.8
Btu/h
42,000
42,000
Btu/h
42,000
42,000
Btu/h
38,500
38,500
1
W
3,080
3,285
A
15.0/13.6
16.0/14.5
W/W
4.00
3.75
-
12.0
11.5
CITY MULTI
04 - 36/11
Branch box
06 - 36/4
dB <A>
49/53
inch (mm)
inch (mm)
m³/min
L/s
cfm
kW
kW
2.8
kW
mm
inch
lb (kg)
(Cooling)
(Heating)
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items
shall be referred to the Installation Manual.
: D.B. 80°F/W.B. 67 °F [D.B.26.7°C/W.B. 19.4°C]
: D.B. 70°F [D.B. 21.1°C]
: D.B. 70°F [D.B. 21.1°C]
cations.
MXZ-SM42NAMHZ2-U1
Ducted
Non-Ducted
Mix
36,000
42,000
42,000
3,000
3,135
3,500
14.6/13.2
15.3/13.8
17.1/15.4
12.0
13.4
12.0
18.5
21.5
19.8
42,000
48,000
48,000
42,000
48,000
48,000
38,500
44,000
44,000
3,520
3,435
3,805
17.2/15.5
16.8/15.2
18.6/16.8
3.50
4.10
3.70
11.0
11.1
10.6
1-phase 208/230 V, 60 Hz
40 A/80 A (When power is supplied separately)
45 A/86 A (When power is supplied from the outdoor unit)
45 A (When power is supplied separately)
51 A (When power is supplied from the outdoor unit)
50 to 130% of outdoor unit capacity
04 - 54/12
06 - 36/5
50/54
3/8 (ø9.52)
5/8 (ø15.88)
Propeller fan × 2
110
1,834
3,885
DC control
0.074 × 2
0
Scroll hermetic compressor × 1
Mitsubishi Electric Corporation
Inverter
2.9
0
FV50S 78oz. (2.3L)
Galvanized Steel Sheet <Munsell 3Y 7.8/ 1.1>
1,338 × 1,050 × 330 (+25)
52-11/16 × 41-11/32 × 13 (+1)
High pressure switch
Overcurrent detection, Overheat detection (Heat sink thermistor)
Compressor thermo, Overcurrent detection
Overheating/Voltage protection
R410A 10 lbs. 9 oz. (4.8kg)
Linear Expansion Valve
278 (126)
Cross n and tube
HIC circuit
Reversed refrigerant circuit
D.B 23 to 115°F [D.B.-5 to 46°C] * 4 * 5 * 6
W.B.-13 to 59°F [W.B.-25 to 15°C]
cations may be subject to change without notice.
]
SMART MULTI
MXZ-SM48NAMHZ2-U1
Ducted
Non-Ducted
Mix
42,000
48,000
48,000
3,965
3,665
4,070
19.4/17.5
17.9/16.2
19.9/18.0
10.6
13.1
11.8
18.0
23.0
19.5
48,000
54,000
54,000
48,000
54,000
54,000
44,000
47,000
47,000
4,265
3,960
4,400
20.8/18.8
19.3/17.5
21.5/19.4
3.30
4.00
3.60
10.0
11.5
10.5
04 - 54/12
06 - 36/8
51/54
3.4
kcal/h = kW × 860
Conversion formula:
Btu/h = kW × 3412
CFM
= m
3
/min × 35.31
Ducted
48,000
4,575
22.3/20.2
10.5
16.0
54,000
54,000
47,000
4,950
24.2/21.8
3.20
9.50
3