RM-GA013
4-1-13. AC Power Cord Wire Dressing
(Non-CISPR)
1) Install AC cord holder to AC power cord at specified position as shown.
2) Then install the AC power cord with holder into AC cord bracket.
1
AC power cord is above
Lead Assy, Earth
Non-CISPR model
60 ± 5mm
Non-CISPR
2
Install AC power cord with
holder into AC cord bracket
AC cord bracket
Figure (a)

4-1-14. AC Power Cord Wire Dressing (CISPR)

1) Install Ferrite Core to AC power cord at specified position as shown.
2) Next, install AC cord holder to AC power cord at specified position.
3) Insert AC power cord into slide, clamp to secure it in position.
4) Lastly, install the AC power cord with holder into AC cord bracket.
3
Attach AC Power Cord into Slide, clamp
AC power cord is above
Lead Assy, Earth
AC cord bracket
CAUTION:
1. Ensure that AC power cord is not stressed whilst inserting it into AC
cord bracket and slider, clamp (CISPR model).
– 14 –
80± 5mm
180 ±
CISPR model
4
Install AC power cord with
holder into AC cord bracket