4-1-5. LVDS Harness and SP Connector Assy

4P Dressing (NON CISPR)
1) Insert LVDS harness to panel as shown.
2) Ensure SP Conn Assy 4P is below LVDS Harness.
Make sure LVDS harness is fully
inserted with direction as shown
Note: When inserting LVDS harness to panel, make sure
it is fully inserted and in the correct direction as shown.

4-1-7. Connector Assy 1P and Inverter Harness Dressing

1) Insert Connector Assy 1P to HT PWB's screw hole and panel's screw hole as shown.
2) Insert Lamp connectors to CN6705; CN6707 (bottom) and CN6702; CN6704 (top) as shown.
Bottom side
1
Conn Assy 1P
45º
SP Conn Assy 4P is below
LVDS Harness
Common for all 19T400 models
CN6705
CN6707
Stand
Lamp wire comes out from beneath GT
2
PWB and to right of stand before connecting
HT PWB
4-1-6. LVDS Harness and SP Connector Assy
4P Dressing ( CISPR)
1) Insert LVDS harness to panel as shown.
2) Ensure SP Conn Assy 4P is below LVDS Harness.
3) Screw the Earth Clamp of LVDS Harness' on to the Main Bracket.
SP Conn Assy 4P is below LVDS Harness
Note: When inserting LVDS harness to panel, make sure
it is fully inserted and in the correct direction as shown.
Top side
CN6702
2
Figure a
– 10 –
Make sure LVDS harness is fully
inserted with direction as Shown
Attach earth clamp and insert screw
Common for all 19T400
Stand
CN6704
Lamp wire comes out from beneath GT
PWB and to right of stand before connecting
Figure b

Advertisement