2.6 Reset Button
The reset button is used to perform a reset to the switch. It is not used in normal cases and can be used for
diagnostic purpose. If any network hanging problem is suspected, it is useful to push the button to reset the
switch without turning off the power. Check whether the network is recovered.
The button can also be used to restore the software configuration settings to factory default values. The
operations are:
Operation
Press the button during system boot-up and release
it after boot-up. The boot-up takes about 27 seconds
and ends with LED diagnostics.
Press the button and release during switch operation
The operations are:
Operation
Press the button and release during switch operation
Press the button until MGT-LED steady ON
2.7 Making UTP Connections
The 10/100/1000 RJ-45 copper ports support the following connection types and distances:
Network Cables
10BASE-T:
2-pair UTP Cat. 3, 4, 5, EIA/TIA-568B 100-ohm
100BASE-TX: 2-pair UTP Cat. 5, EIA/TIA-568B 100-ohm
1000BASE-T: 4-pair UTP Cat. 5 or higher (Cat.5e is recommended), EIA/TIA-568B 100-ohm
Function
Restore factory default settings
Re-boot the switch unit
Function
Reset & boot up the switch. The behavior is
same as power boot procedure.
Boot & restore all factory default settings
-18-