Part name
No.
7
Compressor
8
Reactor
Procedures
1) Perform work of item 1 of 1 and 2, 3, 4, 5.
2) Extract refrigerant gas.
3) Remove the partition board.
(ST2TØ4 × 10L 3 pcs.)
4) Remove the sound-insulation material.
5) Remove terminal cover of the compressor, and
disconnect lead wire of the compressor from
the terminal.
6) Remove pipe connected to the compressor with
a burner.
7) Remove the fixing screw of the bottom plate
and heat exchanger. (ST2TØ4 × 10L 1 pc.)
8) Remove the fixing screw of the bottom plate
and valve fixing plate.
(ST2TØ4 × 10L 1 pc.)
9) Pull upward the refrigeration cycle.
10) Remove NUT (3 pcs. fixing the compressor to
the bottom plate.
1) Perform work of item 1 of 2 and 3.
2) Remove screws fixing the reactors.
(ST2TØ4 × 10L 2 pcs.)