Toshiba RAS-B07G3KVSG-E Service Manual page 119

Indoor/outdoor unit, r32 or r410a inverter
Hide thumbs Also See for RAS-B07G3KVSG-E:
Table of Contents

Advertisement

No.
Part name
6
Fan motor
<To re-installation>
- Check the type name of fan motor.
- Keep connector position and arrange fan
7
Horizontal louver
Procedures
1) Follow the procedure item 3 and 4 .
2) Loosen the set screw of the cross flow fan.
Cross flow fan
3.5 mm
Set screw
3) Remove 2 fixing screws of the motor band.
4) Pull the motor band and the fan motor
outward.
motor wires follow figure.
Fan motor wire
1) Remove shaft of the horizontal louver
from the back body. (First remove 2 the
center shafts then remove the other shafts.)
Body back
Fan motor
Screws
Fan motor
connector
- 119 -
Remarks
Cross flow fan
Hexagon screw driver
Vertical louver
Fan motor
Drain pan
Horizontal louver
Motor band

Advertisement

Table of Contents
loading

Table of Contents