Page 1
Operating Instructions for use by heating contractor Vitotrol 200-E Remote Control VITOTROL 200-E Product may not be exactly as shown IMPORTANT Read and save these instructions for future reference. Please file in Service Binder 5472 513 - 02 03/2022...
Information contained in this and installation of carbon monoxide detectors. Follow the related product documentation must Viessmann maintenance schedule of the boiler contained be read and followed. Failure to do in this manual. so renders the warranty null and void.
Table of Contents Vitotrol 200-E Operating Page Safety, Installation and Warranty Requirements ..... 2 Safety Safety Terminology ........... 2 General Product Information ........... 4 Commissioning ............4 Your System is Factory Set ........4 Tips on Saving Energy ..........5 Tips for Greater Comfort ...........
General Vitotrol 200-E Operating Product Information Vitotrol 200-E Wired remote control for connecting to Viessmann boilers For setting up to 4 heating circuits: Up to 3 set room temperatures (Comfort, Normal, Reduced) can be set Set DHW temperature can be adjusted Holiday program and “Holidays at home”...
General Vitotrol 200-E Operating Tips on Saving Energy Saving energy on central heating Thermostatic valves: Do not overheat your home. Every degree of room Ensure that thermostatic valves are properly adjusted. temperature reduction saves up to 6% on your Radiators: heating bills.
Operation Vitotrol 200-E Operating Operating the Remote Control The remote control allows you to make the following settings from your living space: Room temperatures DHW temperature Operating programs of the heating circuits and DHW heating Holiday program and “Holidays at home”...
Operation Vitotrol 200-E Operating Menu Standard Menu (default display) Two control levels are available, the “Standard menu” (standard display) and the “Extended menu”. Standard menu (standard display) In the standard menu, you can adjust and scan the settings used most frequently:...
Operation Vitotrol 200-E Operating Control System You can make central heating settings for every heating circuit. It is therefore necessary to select the required heating circuit prior to making any adjustments (e.g. room temperature). The following diagram shows you how to make adjustments using the standard set room temperature for heating circuit 2 as an example.
Operation Vitotrol 200-E Operating Quick Select The most important functions can be operated easily using “Quick select”. The “Quick select” functions have a higher priority than functions set in the usual way, e.g. the time program. “Quick select” functions: Extended heating...
Page 10
Operation Vitotrol 200-E Operating Time Program (continued) Setting a time program, using central heating as an example 1. Extended menu: 2. “Indoor environment” 3. If necessary, for the required heating circuit. 4. “Time program” 5. Select part of the week or a day.
Start-up/Shutdown Vitotrol 200-E Operating Starting the “Heating” Operating Program If the “Heating” operating program is switched off, you can switch it on as follows: 1. Extended menu: 2. “Indoor environment” 3. If necessary, for the required heating circuit 4. “Start/stop”...
Central Heating Vitotrol 200-E Operating Setting the Room Temperature Setting the room temperature via the standard menu You can set 3 room temperature levels for each heating Standard menu: circuit: for the required heating circuit Reduced room temperature for “Set the room temperature”.
Central Heating Vitotrol 200-E Operating Temporarily Adjusting the Room Temperature Setting “Extended heating” Extended heating 1. Extended menu: If you wish to heat your rooms to the standard room temperature/comfort room temperature, but the current 2. “Quick select” time program is set to the reduced room temperature, 3.
Central Heating Vitotrol 200-E Operating Adjusting the Room Temperature for Longer Periods at Home (continued) Example Setting “Holidays at home” For Monday and Tuesday, 2 time phases are set 1. Extended menu: respectively. 2. “Quick select” 3. “Holidays at home”...
DHW Heating Vitotrol 200-E Operating Setting the DHW Temperature The functions for setting the DHW are only available if the control unit of your boiler is set to “Detached house”. Delivered condition: During commissioning, the remote control adopts the settings of the boiler control unit.
Adjustments Vitotrol 200-E Operating Setting the Display Contrast You can make the menu texts easier to read. To do so, adjust the contrast of the display to suit the lighting conditions in the room. 1. Extended menu: 2. “Settings” 3. “Contrast”...
Checks Vitotrol 200-E Operating Calling Up Information Subject to the connected components and settings made, you can call up current temperatures (actual temperatures) and operating states. In the extended menu, information is split into groups: “Heating circuit 1” “Heating circuit 2”...
What to do if... Vitotrol 200-E Operating Rooms are Too Cold Cause Remedy Remote control is set incorrectly. Central heating must be enabled. Check the settings and correct if required: Operating program: See the operating instructions for the boiler control unit.
What to do if... Vitotrol 200-E Operating The DHW is Too Hot Cause Remedy Remote control is set incorrectly. Check the set DHW temperature and correct if required: See page 15. The function for increased DHW hygiene (hygiene Wait until the increased DHW hygiene (hygiene function) function) is activated at the boiler control unit: has ended.
Maintenance Vitotrol 200-E Operating Cleaning The appliance surfaces can be cleaned with a commercially available domestic cleaning agent (non scouring). Overview of Extended Menu Note: Subject to the features of your heating system, Note: Subject to the features of your heating system,...
Additional Information Vitotrol 200-E Operating Terminology Standby mode Underfloor heating system Heat generation is switched off. Only frost protection for Underfloor heating systems are slow, low temperature the boiler and the DHW tank is active. No central heating, heating systems and respond only very slowly to short no DHW heating.
Page 22
Additional Information Vitotrol 200-E Operating Terminology (continued) A system may comprise several heating circuits. For example, one heating circuit for the rooms occupied by you and one heating circuit for the rooms of a separate apartment. Heating circuit pump Circulation pump for circulating the heating water in...