120/240 volt 3750 watt generator

Advertisement

Engine
will not start
No electrical
output
Repeated circu# breaker tripping
Generator overheating
No auto
idle
DC does not have power with the
circuit breaker depressed
1.
Low on fuel or oil.
2.
Ignition switch in "Off" position.
3.
Faulty spark plug.
4.
Choke in wrong position.
5.
Fuel shut-off valve in closed
position.
6.
Unit loaded during start-up.
7.
Spark plug wireloose.
1.
Faulty receptacle.
2.
Circuit breaker kicked out.
3.
Defective capacitor.
4.
Faulty powercord.
5.
GFCI switch breaker kicked out (if
equipped)
1.
Overload
2.
Faulty cords or equipment.
1.
Generator overloaded.
2.
Insufficient ventilation.
1. Faulty solenoid
2. Faulty idle control switch
3. Faulty windings in stator
4. Faulty circuit board
5. Faulty wire harness
1. Faulty rectifier
2. Faulty windings in stator
3. Faulty wire harness
CORRECTION
1. Add fuel or oii.
2. Turn to "ON" position
3. Replace spark plug.
4. Adjust chokeaccordingiy.
5. Open fuel shut-off valve.
6,
Removeload
from unit,
7, Attach
wire to spark plug,
1,
Have Service Center replace,
2,
Depress
and reset,
3,
Have Service Center replace
capacitor,
4,
Repair or replace
cord,
5. Depress
and reset
,
2.
Reduce load.
Check for damaged, bare, or
frayed wires on equipment.
Replace.
1. Reduce load.
2. Move to adequate supply of
fresh air.
1. Have Service
Center replace.
2. Have Service
Center replace.
3. Have Service
Center replace.
4. Have Service
Center replace.
5. Have Service
Center replace
1. Have Service Center replace.
2. Have Service Center replace.
3. Have Service Center replace.
16 -- ENG