Service Schedule, Continued
Perform Service at Intervals
Indicated (X)
INTAKE/EXHAUST SYSTEM
Inspect exhaust system components
Replace the air cleaner element
Clean the breather pipe
ELECTRICAL SYSTEM
Keep the battery charged and in good
condition *
Adjust the battery charging alternator
belt tension
Check
and
tighten
connections
Verify proper operation of gauges,
if equipped
Clean battery cables [
ENGINE AND MOUNTING
Check for water, fuel, coolant, and oil
leakage [
]
Retighten all nuts and bolts
Check
tightness
of
[
bolts/vibromounts
Check intake/exhaust valve clearance
and adjust as necessary
Retighten cylinder head bolts
REMOTE CONTROL SYSTEM, ETC.
Check remote control operation
Check compartment condition
(water, fuel, exhaust, coolant, or oil
leaks)
Test run the generator set
GENERATOR
Blow dust out of generator [
* Consult battery manufacturer's instructions.
[ Consult your local distributor/dealer for service.
] Read WARNING found at the beginning of manual regarding moving parts.
TP-5964 7/01
Reference
Section
[
3.6
3.5.2
3.5.1
3.8
electrical
2.4.3
mounting
[
[
2.4
2.3
3.1
Every
Every
50 Hrs.
100 Hrs.
Before
or 1
Starting
Month
Months
X
X
(Break-in
period)
X
X
X
X
X
(Break-in
period)
X
(Break-in
period)
X
X
(Weekly)
Every
Every
150 Hrs.
300 Hrs.
or 3
or 3
or 6
Months
Months
X
X
X
X
X
X
X
X
Section 3 Scheduled Maintenance
Every
500 Hrs.
or Yearly
X
X
X