Section Two Operating The Appliance (Users Instructions) - Infinity 600 FL Owner's Manual

Table of Contents

Advertisement

SECTION TWO Operating the Appliance (users instructions)

To light the appliance using the remote hand set:
a. Press the
button. Continue to hold the button for
approximately 2 seconds and release. When released a bleep
should be heard and the appliance will automatically go
through the ignition sequence and the pilot should ignite. Once
the pilot is alight the appliance will automatically go to the high
setting (approximately 20-25sec).
b. If the ignitor stops sparking and the pilot has failed to light
press the
button for at least 2 seconds and release again a
bleep should be heard. (wait 3 minutes) Then repeat the
lighting procedure.* see note on page 9
a. With the appliance lit, by pressing
setting and vice versa. When Room Thermostat mode is active, the display shows the set temperature value and
the "AUTO" icon will appear on the LCD display. By using the
set. When manual mode is active, the display shows the "MAN" icon plus the flame icon and a five level bar icon
setting. By pressing the
flame. If level 5 is currently active, the icon max
*Note: Due to the nature of the gas, flame variation on LPG models will only be visible on Hi and Lo setting*
b. To switch off the appliance press the
appliance will bleep and then shut off. For pilot setting press the
symbol will appear on the LCD display. Pressing the
c. The appliance can be switch off without using the hand set by removing the appliance batteries located below
the air grill cover. When the batteries are removed there will be a delay (up 3minutes) after which double bleeps
may be heard and shortly after the appliance will extinguish. Ensure that the battery is reconnected once the fire
has been extinguished. The appliance cannot be operated without the use of the handset.
Room Thermostat mode
The remote handset checks the room temperature at a fixed time intervals. Depending on the difference between
set room temperature and the actual room temperature the remote proceeds to modulate in one level steps. Once
the room temperature is reached it moves to standby position pilot only. The icon "PILOT" will appear on the LCD
display. As soon as the actual room temperature falls below the SET room temperature, the system will move from
standby to the high flame level. From this point it will proceed again the modulation process.
Note: Due to the temperature checks at timed intervals, the display temperature on the handset may exceed the
room setting temperature before the appliance defaults to the pilot setting.
www.charltonandjenrick.co.uk
key the operational mode is switched from manual to Room Thermostat
arrow key, the flame picture can be adjusted at five stages between high and low
button for at least 2 seconds and on releasing the button the
arrow key the desired room temperature can be
below the flame icon will appear.
button for 1 second and release. The pilot
will bring the fire back on to main flame.