Advertisement

Quick Links

Owner's Manual
INCLUDES
User, Maintenance, Service, and Installation
Instructions
600 FL
Keep this booklet for service log and future reference
IMPORTANT
This appliance is guaranteed for 12 months subject to conditions. The 5 year extended parts
warranty will only be valid if the annual service recommended in this manual has been
completed and appliance has been registered online.
For use in Great Britain and Ireland.
Literature NO 6125 (ISS 13)

Advertisement

Table of Contents
loading

Summary of Contents for Infinity 600 FL

  • Page 1 Owner’s Manual INCLUDES User, Maintenance, Service, and Installation Instructions 600 FL Keep this booklet for service log and future reference IMPORTANT This appliance is guaranteed for 12 months subject to conditions. The 5 year extended parts warranty will only be valid if the annual service recommended in this manual has been completed and appliance has been registered online.
  • Page 2: Table Of Contents

    Contents EXTENDED FIVE YEAR PARTS WARRANTY ....2 Benchmark Scheme ............. 3 SECTION ONE Introduction (users instructions) ..5 SECTION TWO Operating the Appliance (users EXTENDED FIVE YEAR PARTS instructions) ..............7 WARRANTY SECTION THREE Cleaning (users instructions) ..10 SECTION FOUR Fuel Bed Cleaning and Layout (users In order to validate your extended 5 years parts instructions) ...............
  • Page 3: Benchmark Scheme

    Benchmark Scheme Charlton and Jenrick Ltd is a licensed member of the Benchmark Scheme which aims to improve the standards of installation and commissioning of domestic heating and hot water systems in the UK and to encourage regular servicing to optimise safety, efficiency and performance. Benchmark is managed and promoted by the Heating and Hotwater Industry Council.
  • Page 4 For future reference we suggest you record the following details here, and keep the receipt as proof of purchase. This information may be asked for when you contact the helpdesk. MODEL: INFINITY 600 FL Serial No. This information can be found on the label attached to the packaging and on the data badge, which is located on the base of the appliance behind the control cover.
  • Page 5: Section One Introduction (Users Instructions)

    INTRODUCTION  The 600 FL as been designed and tested to the requirements of EN 613 and is suitable for use in GB (Great Britain) and IE (Ireland). ...
  • Page 6 The 600 FL is battery operated; therefore no mains electrical supply is required. Power to the appliance is provided by 6 high power alkaline 1.5V batteries (C size) (a spare set of 6 C batteries is supplied with the appliance).
  • Page 7: Section Two Operating The Appliance (Users Instructions)

    SECTION TWO Operating the Appliance (users instructions) To light the appliance using the remote hand set: a. Press the button. Continue to hold the button for approximately 2 seconds and release. When released a bleep should be heard and the appliance will automatically go through the ignition sequence and the pilot should ignite.
  • Page 8 To Replace Battery In Hand Set (3 AAA type batteries) Remove the cover from the rear of the handset and fit replacement batteies. Clock Regulation As soon as the batteries are fitted the timer digits will blink. Using the arrow key increase or decrease the hour, minutes and week`s value.
  • Page 9 Child Lock (Handset) To activate `Child Lock` : Press and hold the Mode Key O button for 5 seconds, this will lock and disable the handset and a “padlock” symbol will appear on the bottom of the screen. This can be done while the fire is “off” or “on”. To deactivate this function press and hold the Mode Key O for 5 seconds and the “padlock”...
  • Page 10: Section Three Cleaning (Users Instructions)

    SECTION THREE Cleaning (users instructions) Warning: - Before you clean any part of the appliance ensure that the appliance is turned off and cold. CLEANING: PILOT ASSEMBLY (Before cleaning ensure that the appliance is turned off and cold) In some instances you may experience ignition problems even when the appliance is new. This may be due to the aeration hole in the pilot body being partial blocked with dust, pet hairs, or other foreign matter.
  • Page 11: Section Four Fuel Bed Cleaning And Layout (Users Instructions)

    GLASS CLEANING From time to time it will be necessary to clean the glass panel of your 600 FL. We recommend you use a Ceramic hob cleaner these are available for all leading super markets: - i.e. ASDA, TESCO, SAINSBURY’S Etc.
  • Page 12 Fitting the fire liners  Once the firebox is secured into position fit either the vermiculite or brick back liners supplied.  Position the 2- piece rear liner behind the 3 lugs located at the bottom rear of the firebox. The vermiculite liner has a vertical joint and the brick back has a horizontal joint.
  • Page 13  Place the two log shapes as shown This small pointed edge towards the back of the firebox rested on air tray This log is actually a ‘Y’ shape log This charred edge on show at the front  Place the two log shapes as shown. www.charltonandjenrick.co.uk LT6125 (ISS 13)
  • Page 14  Place the two log shapes as shown.  Place the two log shapes as shown.  Place the two log shapes as shown. LT6125 (ISS 13)
  • Page 15: Section Five General Points (Users Instructions)

    Like all appliances incorporating an aerated burner a low frequency noise may be heard, particularly on the low setting, this is quite normal and does not affect the operation of the appliance. It is advised that a competent person service the 600 FL fire annually. The fire is more likely to provide trouble-free operation.
  • Page 16: Section Six Appliance Data (Installation Instructions)

    SECTION SIX Appliance Data (installation instructions) NATURAL GAS PROPANE GAS Gas Type: CATEGORY I 2 H CATERGORY 1 3 P Gas Pressure: 20 mbar +/- 1.0mbar 37 mbar +/- 1.0mbar Pressure Test Point Location: Gas inlet elbow Gas Input: 5.5 kW Gross (Max.) 5.0kW Gross (Max.) 2.4 kW Gross (Min.) 2.4kW Gross (Max.)
  • Page 17: Section Seven Regulations And Warnings (Installation Instructions)

    SECTION SEVEN Regulations and Warnings (installation instructions)  This appliance must only be installed in Great Britain or Ireland.  The appliance is suitable for use on natural gas only.  GB (Great Britain) This fire does not normally require purpose build ventilation. ...
  • Page 18: Section Eight Siting The Appliance (Installation Instructions)

    SECTION EIGHT Siting the Appliance (installation instructions)  CLASS ONE That is a conventional brick or stone chimney as used for a solid fuel appliance with an effective cross-sectional dimension of 225 x 225 mm (9” x 9”) or a lined flue with a minimum diameter of 125mm (5”). The chimney must have a minimum effective height of at least 3 metres.
  • Page 19 PREPARING THE OPENING FOR INSTALLATION WITH MARBLE SLIPS 725 - 765 mm This area behind the trim/fascia 525 - 555mm must be clear of combustible material and be flat for the seal. Floor 350mm The front face and the base of the fire opening must be flat to ensure that a good seal is formed between the rear and base of the appliance and the chimney to avoid any reduction of natural draught.
  • Page 20: Section Nine To Install The Appliance (Installation Instructions)

    CHECKING THE FLUE AND FIRE OPENING  Check that the chimney conforms to the required specifications as previously stated. Examine the condition and carry out any remedial work including removing any debris from the base.  If the flue has been used for solid fuel it should be swept prior to the installation ...
  • Page 21 CHECKING GAS SOUNDNESS AND RUNNING PRESSURE. *Batteries must be connected before proceeding with any soundness testing*  Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice.  Turn off the gas supply at the external Isolation valve. ...
  • Page 22: Section Ten Checking Operation Of Fire (Installation Instructions)

    SECTION TEN Checking Operation of Fire (installation instructions) REFIT GLASS PANEL AND FIREPLACE FRAME COVERS  Locate the glass panel within the bottom glass retaining slot and push back against the firebox seals.  Locate the glass fixing bracket over the top edge of the glass panel and slide over the two M4 studs.
  • Page 23: Section Eleven Maintenance (Maintenance Instructions)

    SECTION ELEVEN Maintenance (maintenance instructions) GENERAL  Servicing should be carried out annually by a competent person such as a Gas safe-registered person in accordance with the relevant regulations, to ensure the safe and correct operation of the appliance.  Before commencing any service or replacement of parts, turn off the gas supply to the fire.
  • Page 24 REPLACEMENT OF OXY-PILOT ASSEMBLY NOTE: If the pilot assembly is replaced it must be replaced by an identical unit from the same manufacturer and replaced as a complete unit.  Follow the burner tray removal sequence.  Undo the compression nut on the supply pipe at the pilot. ...
  • Page 25: Section Twelve Wiring Diagram (Maintenance Instructions)

    SECTION TWELVE Wiring Diagram (maintenance instructions) Attach to the valve www.charltonandjenrick.co.uk LT6125 (ISS 13)
  • Page 26 LT6125 (ISS 13)
  • Page 27 www.charltonandjenrick.co.uk LT6125 (ISS 13)
  • Page 28 LT6125 (ISS 13)
  • Page 29 Register your appliance online today to active your warranty www.charltonandjenrick.co.uk LT6125 (ISS 13)
  • Page 30: Gas Fire Commissioning Checklist

    GAS FIRE COMMISSIONING CHECKLIST This Commissioning Checklist is to be completed in full by the competent person who commissioned the gas fire as a means of demonstrating compliance with the appropriate Building Regulations and then handed to the customer to keep for future reference.
  • Page 31: Service Record

    SERVICE RECORD It is essential that your gas fire is serviced regularly and that the appropriate Service Interval Record is completed. Service Provider Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manufacturer’s instructions.
  • Page 32 A-0323 MZ (Ng) Product Serial No Prefix ID Label A-0340 MW(LPG) Burner Tray / Box Assembly Log Fuel Bed 1x bag of bark chippings included (5997) Vermiculite (LPG ONLY) Grommet (1092) Top Liner Fitted 7mm Nut Spinner Restrictor Plate with WARNING LABEL Side Covers (5995) Infill Cover (5988) Glass Panel...