¢ Heating thermostat on for humidifier
Situation
Example of
individual
connection
• Example of individual connection
• Operation status
The heating thermostat output for CN47,Output1,Output2,Output3 will be on when comp. on or ex-
ternal heater on.
The heating thermostat output will be off when comp off and external heater off.
8-4. Details of function
Function
setting
Mode
Heating
thermostat on
no. 60
5
60-05
6
60-06
7
60-07
8
60-08
External output: Heating thermostat on
On
Heating operation
Off
On
Heating thermostat
On output
Off
On
Comp. On / Off
Off
On
External heater
output On / Off
Off
On
Fan
Off
Indoor unit
Rotary SW
thermostat on
7
8
9
A
Humidifier
Cool air prevention
- 60 -
External output
Indoor unit fan
Heating
operation
status
CN47
Output3
Not used
Output2
Output1
8. External input and output