Figure 7-2 Entering The Motor Data - Siemens SIMOTICS FD 1LL1 Operating Instructions Manual

Low-voltage motor
Table of Contents

Advertisement

Start-up
7.10 Setting the motor parameters at the converter
5. Enter the appropriate motor data in the "Motor data" table in the "Value" column.
6. Click "Continue" to confirm your entries.
100
– You can find the values for parameters p304...p311 on the motor rating plate.
– The value for parameter p335 (motor cooling method) is encrypted from the motor order
number:
Motor order number
1LL1
1LP1
1LM1/1MM1
1LQ1/1MQ1
1LH1/1MH1
1LN1/1MN1
Figure 7-2
Entering the motor data
Cooling method
IC01
IC06
IC411
IC416
IC71W
IC86W
Parameter p335
0
1
4
5
6
6
SIMOTICS FD 1LL1