Mitsubishi Electric TRANE NTXFKS09A112AA Service Manual page 6

Table of Contents

Advertisement

3-1. OPERATING RANGE
(1) POWER SUPPLY
Rated voltage
208/230 V
Indoor unit
(2) OPERATION
Mode
Condition
Standard temperature
Maximum temperature
Cooling
Minimum temperature
Maximum humidity
Standard temperature
Heating
Maximum temperature
Minimum temperature
3-2. OUTLET AIR SPEED AND COVERAGE
1. Single connection
Model
Mode
HEAT
NTXFKS09A112AA
NTXFKS12A112AA
COOL
HEAT
NTXFKS15A112AA
COOL
HEAT
NTXFKS18A112AA
COOL
2. Multi connection
Model
Mode
HEAT
NTXFKS09A112AA
NTXFKS12A112AA
COOL
HEAT
NTXFKS15A112AA
NTXFKS18A112AA
COOL
OBHT752
Guaranteed voltage (V)
Min. 187
1 phase
60 Hz
DB
80
90
67
70
80
70
Airflow
Function
(CFM)
Dry
417
Dry
417
Wet
354
Dry
470
Dry
431
Wet
366
Dry
470
Dry
491
Wet
417
Airflow
Function
(CFM)
Dry
343
Dry
275
Wet
234
Dry
470
Dry
374
Wet
318
208
230
Max. 253
Intake air temperature (°F)
Indoor
WB
67
73
57
78%
60
67
60
Air speed
Coverage (ft.)
(ft./s.)
20.3
29.6
20.3
29.6
17.2
25.3
22.9
33.3
21.0
30.6
17.8
26.2
22.9
33.3
23.9
34.8
20.3
29.7
Air speed
Coverage (ft.)
(ft./s.)
16.7
24.5
13.4
19.8
11.4
16.9
22.9
33.3
18.2
26.7
15.5
22.8
6
Outdoor
DB
WB
95
115
14
47
43
75
65
-13
-14
The air coverage is the figure
up to the position where the
air speed is 1 ft./s., when air is
blown out horizontally from the
unit properly at the High speed
position.
The coverage should be used
only as a general guideline
since it varies according to the
size of the room and furniture
arranged inside the room.