Mitsubishi Electric Trane NTXWST30A112A Series Installation Manual

Mitsubishi Electric Trane NTXWST30A112A Series Installation Manual

Split-type air conditioners
Hide thumbs Also See for Trane NTXWST30A112A Series:

Advertisement

SPLIT-TYPE AIR CONDITIONERS
INSTALLATION MANUAL
17;:67$$✱ NTXWST36A112A✱
17<:67$$✱ NTYWST36A112A✱
1. BEFORE INSTALLATION
1-1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY
‡ %H VXUH WR UHDG WKHVH VDIHW\ SUHFDXWLRQV DQG LQVWUXFWLRQV
‡ %H VXUH WR REVHUYH WKH ZDUQLQJV DQG FDXWLRQV VSHFL¿HG KHUH
‡ $IWHU UHDGLQJ WKLV PDQXDO EH VXUH WR VWRUH LW ZLWK WKH 23(5$7,1* ,16758&7,216 IRU IXWXUH UHIHUHQFH
‡ 3OHDVH UHSRUW WR \RXU VXSSO\ DXWKRULW\ RU REWDLQ WKHLU FRQVHQW EHIRUH FRQQHFWLQJ WKLV HTXLSPHQW WR WKH SRZHU VXSSO\ V\VWHP
■ Do not install the unit by yourself (user).
,PSURSHU RU LQFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ¿UH HOHFWULF VKRFN LQMXU\ GXH WR
WKH XQLW IDOOLQJ RU ZDWHU OHDNDJH &RQVXOW D TXDOL¿HG LQVWDOOHU RU WKH GHDOHU IURP
whom you purchased the unit.
■ Follow the instructions detailed in the installation manual.
,QFRPSOHWH LQVWDOODWLRQ FRXOG FDXVH ¿UH RU HOHFWULF VKRFN LQMXU\ GXH WR WKH XQLW IDOO-
ing, or leakage of water.
■ When installing the unit, use appropriate protective equipment and tools for
safety.
Failure to do so could cause injury.
■ Install the unit securely in a place that can bear the weight of the unit.
If the installation location cannot bear the weight of the unit, the unit could fall
causing injury.
■ Perform electrical work according to the installation manual and be sure to use
an exclusive circuit. Do not connect other electrical appliances to the circuit.
,I WKH FDSDFLW\ RI WKH SRZHU FLUFXLW LV LQVXI¿FLHQW RU WKHUH LV LQFRPSOHWH HOHFWULFDO
ZRUN LW FRXOG UHVXOW LQ D ¿UH RU DQ HOHFWULF VKRFN
■ Ground the unit correctly.
Do not connect the ground wire to a gas pipe, water pipe, lightning rod or tel-
ephone ground. Defective grounding could cause electric shock.
■ Do not damage the wires.
'DPDJHG ZLUHV FRXOG FDXVH ¿UH
■ Be sure to shut off the main power when setting up the indoor P.C. board or
wiring.
Failure to do so could cause electric shock.
■ 8VH WKH VSHFL¿HG ZLUHV WR VHFXUHO\ FRQQHFW WKH LQGRRU DQG RXWGRRU XQLWV $W-
WDFK WKH ZLUHV ¿UPO\ WR DYRLG DSSO\LQJ VWUHVV WR WKH WHUPLQDO EORFN
,PSURSHU FRQQHFWLRQ FRXOG FDXVH ¿UH
■ 'R QRW LQVWDOO WKH XQLW LQ D SODFH ZKHUH ÀDPPDEOH JDV PD\ OHDN
If gas leaks and accumulates around the unit, it could cause an explosion.
■ Do not use intermediate connection of the power cord or the extension cord.
Do not connect many devices to one AC outlet.
,W FRXOG FDXVH D ¿UH RU DQ HOHFWULF VKRFN
■ 8VH WKH SDUWV SURYLGHG RU VSHFL¿HG SDUWV IRU WKH LQVWDOODWLRQ ZRUN
7KH XVH RI GHIHFWLYH SDUWV FRXOG FDXVH DQ LQMXU\ RU OHDNDJH RI ZDWHU GXH WR D ¿UH
an electric shock, the unit falling, etc.
■ When plugging the power supply plug into the outlet, make sure that there is
no dust, blockage, or loose parts both in the outlet and on the plug. Verify that
the power supply plug is completely in the outlet.
If there is dust, blockage, or loose parts on the power supply plug or the outlet, it could
FDXVH HOHFWULF VKRFN RU ¿UH ,I ORRVH SDUWV DUH IRXQG RQ WKH SRZHU VXSSO\ SOXJ UHSODFH LW
■ Depending on the installation area, install a Ground Fault Interrupt (GFI) circuit
breaker.
If the Ground Fault Interrupt (GFI) circuit breaker is not installed, an electric shock
could occur.
■ Perform the drainage/piping work securely according to the installation manual.
If there is defect in the drainage/piping work, water could drip from the unit, and
damage household items.
When installing multi units, refer to the installation
manual of the multi unit for outdoor unit installation.
Phillips screwdriver
Level
Scale
Utility knife or scissors
3 in. (75 mm) hole saw
Torque wrench
Wrench (or spanner)
WARNING
(Could lead to death or serious injury.)
■ Securely attach the electrical cover to the indoor unit and the service panel to
the outdoor unit.
If the electrical cover of the indoor unit and/or the service panel of the outdoor unit are
QRW DWWDFKHG VHFXUHO\ GXVW ZDWHU HWF FRXOG FROOHFW LQ WKH XQLW DQG FRXOG FDXVH D ¿UH RU
an electric shock.
■ When installing, relocating, or servicing the unit, make sure that no substance
RWKHU WKDQ WKH VSHFL¿HG UHIULJHUDQW 5$ HQWHUV WKH UHIULJHUDQW FLUFXLW
Any presence of foreign substance such as air can cause abnormal pressure rise and
PD\ UHVXOW LQ H[SORVLRQ RU LQMXU\ 7KH XVH RI DQ\ UHIULJHUDQW RWKHU WKDQ WKDW VSHFL¿HG
for the system will cause mechanical failure, system malfunction, or unit breakdown.
In the worst case, this could lead to a serious impediment to securing product safety.
■ Do not discharge the refrigerant into the atmosphere. Check that the refrigerant gas
does not leak after installation has been completed. If refrigerant leaks during
installation, ventilate the room.
,I UHIULJHUDQW FRPHV LQ FRQWDFW ZLWK D ¿UH KDUPIXO JDV FRXOG EH JHQHUDWHG
,I UHIULJHUDQW JDV OHDNV LQGRRUV DQG FRPHV LQWR FRQWDFW ZLWK WKH ÀDPH RI D IDQ
heater, space heater, stove, etc., harmful gases will be generated.
■ Use appropriate tools and piping materials for installation.
The pressure of R410A is 1.6 times higher than R22. Not using the appropriate
tools and materials, or improper installation could cause the pipes to burst causing
an injury.
■ When pumping down the refrigerant, stop the compressor before disconnecting
the refrigerant pipes.
If the refrigerant pipes are disconnected while the compressor is running and the
stop valve is open, air could be drawn in and the pressure in the refrigeration cycle
could become abnormally high, causing the pipes to burst.
■ When installing the unit, securely connect the refrigerant pipes before starting
the compressor.
If the compressor is started before the refrigerant pipes are connected and the
stop valve is open, air could be drawn in and the pressure in the refrigeration cycle
could become abnormally high, causing the pipes to burst.
■ )DVWHQ D ÀDUH QXW ZLWK D WRUTXH ZUHQFK DV VSHFL¿HG LQ WKLV PDQXDO
,I IDVWHQHG WRR WLJKW D ÀDUH QXW FRXOG EUHDN DQG FDXVH UHIULJHUDQW OHDNDJH
■ Install the unit according to national wiring regulations.
CAUTION
(Could lead to serious injury when operated incorrectly.)
■ 'R QRW WRXFK WKH DLU LQOHW RU WKH DOXPLQXP ¿QV RI WKH RXWGRRU XQLW
This could cause injury.
■ Do not install the outdoor unit where small animals may live.
If small animals enter the unit and damage its electrical parts, it could cause a
PDOIXQFWLRQ VPRNH HPLVVLRQ RU ¿UH .HHS WKH DUHD DURXQG WKH XQLW FOHDQ
JG79J423H01
Required Tools for Installation
5/32 in. (4 mm) hexagonal wrench
Flare tool for R410A
Gauge manifold for R410A
Vacuum pump for R410A
Charge hose for R410A
Pipe cutter with reamer

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Trane NTXWST30A112A Series

  • Page 1 JG79J423H01 When installing multi units, refer to the installation manual of the multi unit for outdoor unit installation. Required Tools for Installation SPLIT-TYPE AIR CONDITIONERS Phillips screwdriver 5/32 in. (4 mm) hexagonal wrench INSTALLATION MANUAL Level Flare tool for R410A Scale Gauge manifold for R410A 17;:67$$✱...
  • Page 2: Selecting The Installation Location

    1-2. SELECTING THE INSTALLATION LOCATION INDOOR UNIT Note: Note: ‡ :KHUH DLUÀRZ LV QRW EORFNHG ,Q URRPV ZKHUH LQYHUWHU W\SH ÀXRUHVFHQW ODPSV DUH XVHG ‡ ,W LV DGYLVDEOH WR PDNH D SLSLQJ ORRS QHDU RXWGRRU XQLW ‡ :KHUH FRRO DLU DVSUHDGV RYHU WKH HQWLUH URRP the signal from the wireless remote controller may not be so as to reduce vibration.
  • Page 3: Installation Diagram

    1-4. INSTALLATION DIAGRAM Wall hole cover (D) Use the wall hole sleeve Indoor unit (C) to prevent indoor/ Seal the wall hole gap with putty (H). outdoor connecting wire ACCESSORIES (A) from contacting metal Check the following parts before installation. Wall hole Attach the pipe to parts in the wall and to...
  • Page 4: Indoor Unit Installation

    2. INDOOR UNIT INSTALLATION 2-1. ATTACHING THE INSTALLATION PLATE 2-13/16 in. (70 mm) or more Ceiling ‡ )LQG D VWXG LQ WKH ZDOO WR DWWDFK LQVWDOODWLRQ SODWH  KRUL]RQWDOO\ E\ WLJKWHQLQJ WKH ¿[LQJ 5-1/8 in. (130 mm) or more for left and left back piping (using spacer) VFUHZV  ¿UPO\ ‡...
  • Page 5: Pipe Forming And Drain Piping

    2-4. INSTALLING THE L-JOINT 1) Install L-joint (10) on the back of the unit. Position L-joint (10) according to the piping direction. (Fig. 1) In case of bottom piping (Fig. 2) ‡ &XW /MRLQW  DW WKH SRVLWLRQ VKRZQ LQ )LJ  ‡...
  • Page 6: Drain Piping

    Rear or bottom piping  3ODFH WKH UHIULJHUDQW SLSLQJ DQG WKH GUDLQ KRVH WRJHWKHU WKHQ ¿UPO\ DSSO\ SLSLQJ WDSH * from the end. 2) Insert the piping and the drain hose into the wall hole sleeve (C), and attach the upper part of the indoor unit on the installation plate (1).
  • Page 7: Purging Procedures, Leak Test, And Test Run

    A inch (mm) Tightening torque No good Good Pipe diameter Clutch Clutch Wing nut inch ft-lb inch (mm) type tool type tool type tool 1‡P Copper (mm) NJI‡FP pipe for R410A for R22 for R22 21/32 10 to 13 ø 1/4 (6.35) 13.7 to 17.7 Tilted Uneven Burred...
  • Page 8 To stop operation, press the E.O. SW several times until all LED lamps turn off. Refer to operating instructions for details. WARNING MITSUBISHI ELECTRIC TRANE HVAC US LLC When pumping down the refrigerant, stop the compressor before disconnecting HEAD OFFICE: 1340 SATELLITE BOULEVARD, SUWANEE, GA 30024, USA...

Table of Contents