Sas Subsystem Base Function Storage Configuration With The Split-Disk Feature; Sas Subsystem Expanded Function Configuration - IBM Power System 9009-41G Manual

Sas subsystem
Hide thumbs Also See for Power System 9009-41G:
Table of Contents

Advertisement

• Two 8x mini SAS HD cables
The base function storage configuration for 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, and
9223-42S systems includes:
• One PCIe3 x8 SAS RAID internal adapter 6 Gb, with RAID 0,10,5,6
• One base function disk drive backplane that supports 12x SFF (2.5") bays
• One RDX bay
• Two 8x mini SAS HD cables
On the base function disk drive backplane, the disks are directly attached to the SAS adapter, and uses
Virtual SCSI Enclosure Services (VSES) for controlling the light-emitting diode (LED) and system power.
The RDX drive utilizes one of the USB 3.0 ports from the embedded USB 3.0 controller.
SAS subsystem base function storage configuration with the split-disk feature for the
5105-22E, 9008-22L, 9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G,
9223-22H, 9223-22S, 9223-42H, or 9223-42S
This configuration uses the base function disk drive backplane with the split-disk feature.
The base function storage configuration with split-disk feature for 5105-22E, 9008-22L, 9009-22A,
9009-22G, 9223-22H, and 9223-22S systems includes:
• Two PCIe3 x8 SAS RAID internal adapters 6 Gb, with RAID 0,10,5,6
• One base function disk drive backplane that supports 8x SFF (2.5") bays, with disks split as 4+4.
• Two 8x mini SAS HD cables
The base function storage configuration with split-disk feature for 9009-41A, 9009-41G, 9009-42A,
9009-42G, 9223-42H, and 9223-42S systems includes:
• Two PCIe3 x8 SAS RAID internal adapters 6 Gb, with RAID 0,10,5,6
• One RDX bay
• One base function disk drive backplane that supports 12x SFF (2.5") bays, with disks split as 6+6.
• Two 8x mini SAS HD cables
On the base function disk drive backplane, the disks are directly attached to the SAS adapter, and uses
Virtual SCSI Enclosure Services (VSES) for controlling the light-emitting diode (LED) and system power.
The RDX drive utilizes one of the USB 3.0 ports from the embedded USB 3.0 controller.
SAS subsystem expanded function configuration for the 5105-22E, 9008-22L, 9009-22A,
9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H,
or 9223-42S
This configuration uses the expanded function disk drive backplane.
The expanded function storage configuration for 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H,
or 9223-22S systems includes:
• One expanded function PCIe3 x8 Cache SAS RAID Internal adapters 6 Gb, with RAID 0, 5, 6, 10, 5T2,
6T2, and 10T2
• One 2U disk drive backplane which supports 8x SFF (2.5") bays
• One 8x SAS HD cables
One external SAS 4x port is supported with the expanded function storage configuration. The SAS port
connector is located on the rear bulk head. The external SAS port is used for expansion to external SAS
storage drawers.
The expanded function RAID storage configuration for 9009-41A, 9009-41G, 9009-42A, 9009-42G,
9223-42H, or 9223-42S systems includes:
SAS subsystem for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A,
9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S 9

Advertisement

Table of Contents
loading

Table of Contents